IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

798

matching recommendations
Reset
SIC 373 Ship And Boat Building And Repairing
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
LL0202 # 05 Y:2004 05 2004 INSTALL TIMERS ON LIGHT SWITCHES IN LITTLE USED AREAS $3,376 $135 Not Implemented
LL0202 # 06 Y:2004 06 2004 INSTALL OCCUPANCY SENSORS $1,329 $390 Not Implemented
LL0202 # 07 Y:2004 07 2004 USE PHOTOCELL CONTROLS $726 $150 Not Implemented
LL0202 # 08 Y:2004 08 2004 REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS $442 $198 Not Implemented
LL0201 # 01 Y:2004 01 2004 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $8,219 $5,615 Implemented
LL0201 # 02 Y:2004 02 2004 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $6,772 $3,240 Implemented
LL0201 # 03 Y:2004 03 2004 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $4,084 $30 Implemented
LL0201 # 04 Y:2004 04 2004 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $2,265 $195 Implemented
LL0201 # 05 Y:2004 05 2004 USE PHOTOCELL CONTROLS $1,522 $300 Implemented
LL0201 # 06 Y:2004 06 2004 REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS $227 $198 Implemented
LL0201 # 07 Y:2004 07 2004 INSTALL OCCUPANCY SENSORS $151 $90 Implemented
LL0201 # 08 Y:2004 08 2004 BEGIN A PRACTICE OF PREDICTIVE / PREVENTATIVE MAINTENANCE $2,500 $60 Implemented
MI0089 # 01 Y:2004 01 2004 CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE $13,096 $600 Not Implemented
MI0089 # 02 Y:2004 02 2004 TURN OFF EQUIPMENT WHEN NOT IN USE $22,325 $2,300 Implemented
MI0089 # 03 Y:2004 03 2004 CHECK FOR ACCURACY OF UTILITY / POWER METERS $15,302 $270 Not Implemented
MI0089 # 04 Y:2004 04 2004 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $5,010 $590 Implemented
MI0089 # 05 Y:2004 05 2004 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $25,036 $50 Implemented
MI0089 # 06 Y:2004 06 2004 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $8,772 $25,286 Implemented
MI0089 # 07 Y:2004 07 2004 USE OPTIMUM SIZE AND CAPACITY EQUIPMENT $1,783 $4,328 Not Implemented
LL0200 # 01 Y:2004 01 2004 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $23,139 $810 Implemented
LL0200 # 02 Y:2004 02 2004 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $14,598 $11,757 Not Implemented
LL0200 # 03 Y:2004 03 2004 INSTALL OCCUPANCY SENSORS $10,904 $960 Not Implemented
LL0200 # 04 Y:2004 04 2004 USE PHOTOCELL CONTROLS $8,001 $420 Implemented
LL0200 # 05 Y:2004 05 2004 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $7,518 $30 Implemented