Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
4,140
matching recommendationsSIC | 38 | Instruments And Related Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
CO0008 # 03 Y:1984 | 03 | 1984 | INSTALL TIMERS AND/OR THERMOSTATS | $6,065 | $597 | Implemented |
CO0008 # 04 Y:1984 | 04 | 1984 | RECOVER WASTE HEAT FROM EQUIPMENT | $305 | $200 | Not Implemented |
CO0008 # 05 Y:1984 | 05 | 1984 | INSTALL OR UPGRADE INSULATION ON HVAC DISTRIBUTION SYSTEMS | $253 | $24 | Not Implemented |
CO0008 # 06 Y:1984 | 06 | 1984 | SEPARATE CONTROLS OF AIR HANDLERS FROM AC/ HEATING SYSTEMS | $1,255 | $500 | Implemented |
KU0139 # 01 Y:1984 | 01 | 1984 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,499 | $5,941 | Not Implemented |
KU0139 # 02 Y:1984 | 02 | 1984 | RECOVER WASTE HEAT FROM EQUIPMENT | $1,988 | $3,000 | Not Implemented |
KU0139 # 03 Y:1984 | 03 | 1984 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $818 | $100 | Not Implemented |
KU0139 # 04 Y:1984 | 04 | 1984 | USE DEMAND CONTROLLER OR LOAD SHEDDER | $1,181 | $1,600 | Not Implemented |
KU0139 # 05 Y:1984 | 05 | 1984 | IMPROVE LUBRICATION PRACTICES | $593 | $500 | Not Implemented |
KU0139 # 06 Y:1984 | 06 | 1984 | INSTALL AUTOMATIC STACK DAMPER | $389 | $500 | Not Implemented |
KU0139 # 07 Y:1984 | 07 | 1984 | SHUT OFF PILOTS IN STANDBY EQUIPMENT | $103 | $0 | Not Implemented |
KU0139 # 08 Y:1984 | 08 | 1984 | REDUCE HOT WATER TEMPERATURE TO THE MINIMUM REQUIRED | $118 | $0 | Not Implemented |
KU0139 # 09 Y:1984 | 09 | 1984 | INSULATE BARE EQUIPMENT | $148 | $64 | Not Implemented |
GT0224 # 01 Y:1984 | 01 | 1984 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $390 | $300 | Implemented |
GT0224 # 02 Y:1984 | 02 | 1984 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $1,340 | $2,300 | Not Implemented |
GT0224 # 03 Y:1984 | 03 | 1984 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,510 | $2,350 | Implemented |
GT0224 # 04 Y:1984 | 04 | 1984 | DISCONNECT BALLASTS | $60 | $50 | Implemented |
GT0224 # 05 Y:1984 | 05 | 1984 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $70 | $149 | Implemented |
GT0224 # 06 Y:1984 | 06 | 1984 | UTILIZE OUTSIDE AIR INSTEAD OF CONDITIONED AIR FOR DRYING | $180 | $350 | Not Implemented |
GT0224 # 07 Y:1984 | 07 | 1984 | USE ONLY AMOUNT OF AIR NECESSARY TO PREVENT EXPLOSION HAZARD | $1,190 | $3,000 | Not Implemented |
GT0224 # 08 Y:1984 | 08 | 1984 | USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE | $1,780 | $11,625 | Not Implemented |
TN0208 # 01 Y:1984 | 01 | 1984 | AIR CONDITION ONLY SPACE NECESSARY | $2,708 | $132 | Not Implemented |
TN0208 # 02 Y:1984 | 02 | 1984 | INSTALL STORM WINDOWS AND DOORS | $731 | $123 | Not Implemented |
TN0208 # 03 Y:1984 | 03 | 1984 | SHUT OFF PILOTS IN STANDBY EQUIPMENT | $120 | $10 | Not Implemented |
TN0213 # 01 Y:1984 | 01 | 1984 | USE SEPARATE SWITCHES ON PERIMETER LIGHTING WHICH MAY BE TURNED OFF WHEN NATURAL LIGHT IS AVAILABLE | $375 | $1,240 | Not Implemented |