Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

1,723

matching recommendations
Reset
SIC 382 Measuring And Controlling Devices
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
NV0006 # 01 Y:1994 01 1994 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $3,709 $-175 Implemented
NV0006 # 02 Y:1994 02 1994 IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS $2,218 $3,780 Not Implemented
NV0006 # 03 Y:1994 03 1994 INSTALL OCCUPANCY SENSORS $914 $454 Not Implemented
NV0006 # 04 Y:1994 04 1994 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $554 $240 Implemented
NV0006 # 05 Y:1994 05 1994 OPTIMIZE PLANT POWER FACTOR $807 $2,250 Not Implemented
NV0006 # 06 Y:1994 06 1994 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $394 $30 Implemented
SD0088 # 01 Y:1994 01 1994 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $5,963 $4,300 Implemented
SD0088 # 02 Y:1994 02 1994 UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED $6,722 $200 Implemented
SD0088 # 03 Y:1994 03 1994 INSULATE BARE EQUIPMENT $376 $235 Implemented
SD0088 # 04 Y:1994 04 1994 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $3,853 $150 Implemented
SD0088 # 05 Y:1994 05 1994 USE OPTIMUM SIZE AND CAPACITY EQUIPMENT $117,014 $245,000 Implemented
SD0088 # 06 Y:1994 06 1994 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $40,436 $95,019 Implemented
SD0088 # 07 Y:1994 07 1994 INSTALL SPECTRAL REFLECTORS / DELAMP $39,115 $43,220 Implemented
SD0088 # 08 Y:1994 08 1994 INSTALL TIMERS ON LIGHT SWITCHES IN LITTLE USED AREAS $4,548 $810 Implemented
MO0114 # 01 Y:1994 01 1994 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $2,143 $8,141 Not Implemented
MO0114 # 02 Y:1994 02 1994 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $902 $374 Not Implemented
MO0114 # 03 Y:1994 03 1994 REPLACE CITY WATER WITH RECYCLED WATER VIA COOLING TOWER $3,768 $2,845 Not Implemented
MO0114 # 04 Y:1994 04 1994 KEEP DOORS AND WINDOWS SHUT WHEN NOT ON USE $1,617 $4,864 Not Implemented
MO0114 # 05 Y:1994 05 1994 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $627 $405 Not Implemented
MO0114 # 06 Y:1994 06 1994 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $900 $1,052 Implemented
MO0114 # 07 Y:1994 07 1994 USE SYNTHETIC LUBRICANT $722 $768 Not Implemented
MO0114 # 08 Y:1994 08 1994 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $541 $90 Not Implemented
MO0114 # 09 Y:1994 09 1994 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS $825 $1,317 Not Implemented
MO0114 # 10 Y:1994 10 1994 CLOSE HOLES AND OPENINGS IN BUILDING SUCH AS BROKEN WINDOWS $680 $190 Not Implemented
MO0114 # 11 Y:1994 11 1994 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS $579 $1,317 Not Implemented