Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
157
matching recommendationsSIC | 3821 | Laboratory Apparatus And Furniture |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
SD0135 # 07 Y:1996 | 07 | 1996 | RECOVER AND REUSE WASTE MATERIAL | $100 | $0 | Implemented |
SD0135 # 08 Y:1996 | 08 | 1996 | LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER | $100 | $150 | Implemented |
SD0136 # 01 Y:1996 | 01 | 1996 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $2,889 | $3,260 | Implemented |
SD0136 # 02 Y:1996 | 02 | 1996 | PREHEAT COMBUSTION AIR WITH WASTE HEAT | $2,074 | $2,083 | Implemented |
SD0136 # 03 Y:1996 | 03 | 1996 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,321 | $40 | Implemented |
SD0136 # 04 Y:1996 | 04 | 1996 | USE OPTIMUM THICKNESS INSULATION | $1,905 | $651 | Implemented |
SD0136 # 05 Y:1996 | 05 | 1996 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,979 | $5,928 | Implemented |
SD0136 # 06 Y:1996 | 06 | 1996 | INSTALL SPECTRAL REFLECTORS / DELAMP | $6,002 | $4,080 | Implemented |
SD0136 # 07 Y:1996 | 07 | 1996 | INSTALL OCCUPANCY SENSORS | $1,471 | $1,001 | Implemented |
SD0136 # 08 Y:1996 | 08 | 1996 | REDUCE SCRAP PRODUCTION | $56,160 | $0 | Implemented |
AM0265 # 01 Y:1996 | 01 | 1996 | USE A LESS EXPENSIVE METHOD OF WASTE REMOVAL | $3,100 | $750 | Implemented |
AM0265 # 02 Y:1996 | 02 | 1996 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,260 | $760 | Implemented |
AM0265 # 03 Y:1996 | 03 | 1996 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,550 | $240 | Implemented |
AM0265 # 04 Y:1996 | 04 | 1996 | PAY UTILITY BILLS ON TIME | $1,010 | $0 | Not Implemented |
AM0265 # 05 Y:1996 | 05 | 1996 | RECOVER WASTE HEAT FROM EQUIPMENT | $860 | $380 | Not Implemented |
AM0265 # 06 Y:1996 | 06 | 1996 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $200 | $300 | Implemented |
ME0128 # 01 Y:1994 | 01 | 1994 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $2,591 | $2,250 | Implemented |
ME0128 # 02 Y:1994 | 02 | 1994 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $887 | $100 | Not Implemented |
ME0128 # 03 Y:1994 | 03 | 1994 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $938 | $20 | Implemented |
ME0128 # 04 Y:1994 | 04 | 1994 | CLOSE HOLES AND OPENINGS IN BUILDING SUCH AS BROKEN WINDOWS | $1,845 | $1,120 | Implemented |
ME0128 # 05 Y:1994 | 05 | 1994 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $2,886 | $3,000 | Not Implemented |
ME0128 # 06 Y:1994 | 06 | 1994 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $483 | $450 | Implemented |
AM0192 # 01 Y:1993 | 01 | 1993 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $6,950 | $12,850 | Implemented |
AM0192 # 02 Y:1993 | 02 | 1993 | OPTIMIZE PLANT POWER FACTOR | $3,640 | $5,500 | Not Implemented |
AM0192 # 03 Y:1993 | 03 | 1993 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $210 | $240 | Implemented |