Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
18
matching recommendationsSIC | 384 | Medical Instruments And Supplies |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
CO0008 # 02 Y:1984 | 02 | 1984 | USE DEMAND CONTROLLER OR LOAD SHEDDER | $3,146 | $4,000 | Not Implemented |
CO0008 # 03 Y:1984 | 03 | 1984 | INSTALL TIMERS AND/OR THERMOSTATS | $6,065 | $597 | Implemented |
CO0008 # 04 Y:1984 | 04 | 1984 | RECOVER WASTE HEAT FROM EQUIPMENT | $305 | $200 | Not Implemented |
CO0008 # 05 Y:1984 | 05 | 1984 | INSTALL OR UPGRADE INSULATION ON HVAC DISTRIBUTION SYSTEMS | $253 | $24 | Not Implemented |
CO0008 # 06 Y:1984 | 06 | 1984 | SEPARATE CONTROLS OF AIR HANDLERS FROM AC/ HEATING SYSTEMS | $1,255 | $500 | Implemented |
CO0008 # 01 Y:1984 | 01 | 1984 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,129 | $3,063 | Implemented |
GT0224 # 04 Y:1984 | 04 | 1984 | DISCONNECT BALLASTS | $60 | $50 | Implemented |
GT0224 # 08 Y:1984 | 08 | 1984 | USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE | $1,780 | $11,625 | Not Implemented |
GT0224 # 07 Y:1984 | 07 | 1984 | USE ONLY AMOUNT OF AIR NECESSARY TO PREVENT EXPLOSION HAZARD | $1,190 | $3,000 | Not Implemented |
GT0224 # 06 Y:1984 | 06 | 1984 | UTILIZE OUTSIDE AIR INSTEAD OF CONDITIONED AIR FOR DRYING | $180 | $350 | Not Implemented |
GT0224 # 05 Y:1984 | 05 | 1984 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $70 | $149 | Implemented |
GT0224 # 03 Y:1984 | 03 | 1984 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,510 | $2,350 | Implemented |
GT0224 # 02 Y:1984 | 02 | 1984 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $1,340 | $2,300 | Not Implemented |
GT0224 # 01 Y:1984 | 01 | 1984 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $390 | $300 | Implemented |
TN0202 # 01 Y:1984 | 01 | 1984 | LOWER CEILING TO REDUCE CONDITIONED SPACE | $283 | $3,500 | Implemented |
TN0202 # 02 Y:1984 | 02 | 1984 | REDUCE VENTILATION AIR | $48 | $250 | Implemented |
TN0202 # 03 Y:1984 | 03 | 1984 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $87 | $20 | Implemented |
TN0202 # 04 Y:1984 | 04 | 1984 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $16 | $0 | Implemented |