Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
22
matching recommendationsSIC | 3841 | Surgical And Medical Instruments |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
MA0076 # 07 Y:1986 | 07 | 1986 | INSTALL STORM WINDOWS AND DOORS | $432 | $1,114 | Not Implemented |
MA0076 # 06 Y:1986 | 06 | 1986 | RECOVER AND REUSE COOLING WATER | $1,226 | $660 | Not Implemented |
MA0076 # 05 Y:1986 | 05 | 1986 | USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE | $882 | $3,588 | Implemented |
MA0076 # 04 Y:1986 | 04 | 1986 | RECOVER WASTE HEAT FROM EQUIPMENT | $1,822 | $1,100 | Not Implemented |
MA0076 # 01 Y:1986 | 01 | 1986 | USE DIRECT AIR SUPPLY TO EXHAUST HOODS | $3,524 | $6,000 | Implemented |
MA0076 # 02 Y:1986 | 02 | 1986 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $526 | $77 | Implemented |
MA0076 # 03 Y:1986 | 03 | 1986 | USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE | $712 | $2,050 | Not Implemented |
AT0050 # 02 Y:1986 | 02 | 1986 | UTILIZE OUTSIDE AIR INSTEAD OF CONDITIONED AIR FOR DRYING | $6,892 | $1,700 | Not Implemented |
AT0050 # 05 Y:1986 | 05 | 1986 | REDUCE VENTILATION AIR | $8,542 | $203 | Not Implemented |
AT0050 # 04 Y:1986 | 04 | 1986 | RECOVER WASTE HEAT FROM EQUIPMENT | $361 | $300 | Not Implemented |
AT0050 # 03 Y:1986 | 03 | 1986 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $14,822 | $20,000 | Not Implemented |
AT0050 # 01 Y:1986 | 01 | 1986 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $859 | $400 | Implemented |
OK0198 # 01 Y:1986 | 01 | 1986 | COVER OPEN TANKS | $1,722 | $426 | Not Implemented |
OK0198 # 02 Y:1986 | 02 | 1986 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $340 | $60 | Not Implemented |
OK0198 # 03 Y:1986 | 03 | 1986 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $101 | $49 | Not Implemented |
OK0198 # 04 Y:1986 | 04 | 1986 | UTILIZE AN EVAPORATIVE AIR PRE-COOLER OR OTHER HEAT EXCHANGER IN AC SYSTEM | $5,532 | $22,000 | Not Implemented |
OK0198 # 05 Y:1986 | 05 | 1986 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $8,027 | $276 | Implemented |
OK0198 # 07 Y:1986 | 07 | 1986 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,856 | $3,272 | Implemented |
OK0184 # 01 Y:1986 | 01 | 1986 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $796 | $50 | Implemented |
OK0184 # 02 Y:1986 | 02 | 1986 | USE DEMAND CONTROLLER OR LOAD SHEDDER | $1,732 | $1,800 | Implemented |
OK0184 # 03 Y:1986 | 03 | 1986 | USE HIGHEST TEMPERATURE FOR CHILLING OR COLD STORAGE | $2,324 | $1,200 | Implemented |
OK0184 # 04 Y:1986 | 04 | 1986 | INSTALL TIMERS AND/OR THERMOSTATS | $6,465 | $2,800 | Implemented |