IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

27

matching recommendations
Reset
SIC 3999 Manufacturing Industries, Nec
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
HO0116 # 01 Y:1995 01 1995 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,234 $761 Not Implemented
HO0116 # 02 Y:1995 02 1995 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $247 $374 Not Implemented
HO0116 # 03 Y:1995 03 1995 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $151 $305 Not Implemented
HO0116 # 04 Y:1995 04 1995 INSTALL / REPAIR INSULATION ON STEAM LINES $96 $53 Not Implemented
HO0116 # 05 Y:1995 05 1995 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $229 $500 Not Implemented
HO0116 # 06 Y:1995 06 1995 KEEP BOILER TUBES CLEAN $2,908 $3,000 Not Implemented
HO0116 # 07 Y:1995 07 1995 COMBINE UTILITY METERS $400 $0 Implemented
HO0116 # 08 Y:1995 08 1995 APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES $565 $0 Not Implemented
NC0064 # 07 Y:1995 07 1995 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $2,764 $1,570 Not Implemented
NC0064 # 06 Y:1995 06 1995 INSULATE BARE EQUIPMENT $2,830 $278 Not Implemented
NC0064 # 05 Y:1995 05 1995 INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT $277 $750 Not Implemented
NC0064 # 01 Y:1995 01 1995 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $221 $250 Implemented
NC0064 # 02 Y:1995 02 1995 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,813 $5,700 Implemented
NC0064 # 03 Y:1995 03 1995 INSTALL SPECTRAL REFLECTORS / DELAMP $398 $560 Implemented
NC0064 # 04 Y:1995 04 1995 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $7,568 $780 Implemented
HO0108 # 02 Y:1995 02 1995 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $311 $436 Implemented
HO0108 # 04 Y:1995 04 1995 KEEP BOILER TUBES CLEAN $1,420 $2,000 Implemented
HO0108 # 03 Y:1995 03 1995 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $354 $317 Implemented
HO0108 # 01 Y:1995 01 1995 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $264 $200 Implemented
UL0126 # 01 Y:1995 01 1995 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $34,745 $2,000 Implemented
UL0126 # 02 Y:1995 02 1995 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $2,272 $40 Not Implemented
UL0126 # 03 Y:1995 03 1995 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $1,595 $40 Implemented
UL0126 # 04 Y:1995 04 1995 OPTIMIZE PLANT POWER FACTOR $24,600 $16,488 Not Implemented
UD0452 # 01 Y:1995 01 1995 CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE $620 $0 Not Implemented
UD0452 # 02 Y:1995 02 1995 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS $8,950 $0 Implemented