IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

81

matching recommendations
Reset
SIC 70 Finance, Insurance, And Real Estate
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
LS1922 # 03 Y:2022 03 2022 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $6,968 $10,554 Implemented
LS1922 # 04 Y:2022 04 2022 USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE $11,810 $34,840 Not Implemented
LS1822 # 02 Y:2022 02 2022 REPLACE FOSSIL FUEL EQUIPMENT WITH ELECTRICAL EQUIPMENT $2,555 $1,292 Not Implemented
LS1822 # 03 Y:2022 03 2022 KEEP DOORS AND WINDOWS SHUT WHEN NOT ON USE $190 $125 Not Implemented
LS1822 # 04 Y:2022 04 2022 INSTALL OCCUPANCY SENSORS $49 $50 Implemented
LS1822 # 05 Y:2022 05 2022 USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE $6,150 $23,430 Implemented
LS1822 # 01 Y:2022 01 2022 REDUCE HEAT GAIN BY WINDOW TINTING $30,799 $2,056 Implemented
LS1722 # 04 Y:2022 04 2022 USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE $13,847 $38,610 Not Implemented
LS1722 # 03 Y:2022 03 2022 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS $84 $110 Not Implemented
LS1722 # 02 Y:2022 02 2022 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $2,524 $1,910 Implemented
LS1722 # 01 Y:2022 01 2022 PAY BILLS ON TIME TO AVOID LATE FEES $3,204 $0 Implemented
LS1722 # 05 Y:2022 05 2022 REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL $7,108 $22,697 Implemented
LS1805 # 01 Y:2018 01 2018 REDUCE HEAT GAIN BY WINDOW TINTING $30,024 $47,457 Not Implemented
LS1805 # 02 Y:2018 02 2018 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $1,734 $3,540 Not Implemented
LS1805 # 03 Y:2018 03 2018 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $3,085 $13,250 Not Implemented
WV0475 # 14 Y:2013 14 2013 INSTALL / REPAIR INSULATION ON STEAM LINES $1,243 $1,168 Not Implemented
WV0475 # 01 Y:2013 01 2013 REDUCE VENTILATION AIR $80,805 $74,600 Not Implemented
WV0475 # 02 Y:2013 02 2013 INSTALL PARTITIONS TO REDUCE SIZE OF CONDITIONED SPACE $62,278 $279,714 Not Implemented
WV0475 # 16 Y:2013 16 2013 DEVELOP A REPAIR/REPLACE POLICY $260 $160 Not Implemented
WV0475 # 15 Y:2013 15 2013 ESTABLISH A PREDICTIVE MAINTENANCE PROGRAM $715 $1,000 Not Implemented
WV0475 # 03 Y:2013 03 2013 USE DEMAND CONTROLLER OR LOAD SHEDDER $29,974 $21,000 Not Implemented
WV0475 # 13 Y:2013 13 2013 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS $1,869 $1,152 Implemented
WV0475 # 12 Y:2013 12 2013 INSTALL TIMERS AND/OR THERMOSTATS $2,071 $750 Implemented
WV0475 # 11 Y:2013 11 2013 IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS $2,308 $8,400 Not Implemented
WV0475 # 10 Y:2013 10 2013 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $3,008 $0 Implemented