Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
417
matching recommendationsSIC | 821 | Elementary And Secondary Schools |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UD1120 # 02 Y:2025 | 02 | 2025 | UTILIZE A LESS EXPENSIVE COOLING METHOD | $861 | $2,000 | n/a |
UD1120 # 01 Y:2025 | 01 | 2025 | UTILIZE A LESS EXPENSIVE COOLING METHOD | $1,599 | $2,000 | n/a |
UD1120 # 05 Y:2025 | 05 | 2025 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $630 | $30,000 | n/a |
UD1120 # 04 Y:2025 | 04 | 2025 | UTILIZE A LESS EXPENSIVE COOLING METHOD | $120 | $300 | n/a |
LS0925 # 01 Y:2025 | 01 | 2025 | INSTALL OCCUPANCY SENSORS | $3,332 | $240 | n/a |
LS0925 # 04 Y:2025 | 04 | 2025 | USE PHOTOCELL CONTROLS | $324 | $1,169 | n/a |
LS0925 # 02 Y:2025 | 02 | 2025 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $7,709 | $9,647 | n/a |
LS0925 # 03 Y:2025 | 03 | 2025 | USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE | $7,198 | $10,200 | n/a |
LS0825 # 03 Y:2025 | 03 | 2025 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $6,793 | $5,074 | n/a |
LS0825 # 01 Y:2025 | 01 | 2025 | CHILL WATER TO THE HIGHEST TEMPERATURE POSSIBLE | $8,927 | $500 | n/a |
LS0825 # 04 Y:2025 | 04 | 2025 | CLEAN OR COLOR ROOF TO REDUCE SOLAR LOAD | $6,367 | $24,944 | n/a |
LS0825 # 02 Y:2025 | 02 | 2025 | REDUCE HEAT GAIN BY WINDOW TINTING | $11,016 | $2,940 | n/a |
AM0955 # 03 Y:2025 | 03 | 2025 | USE DOUBLE OR TRIPLE GLAZED WINDOWS TO MAINTAIN HIGHER RELATIVE HUMIDITY AND TO REDUCE HEAT LOSSES | $2,639 | $69,318 | n/a |
AM0955 # 01 Y:2025 | 01 | 2025 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $349 | $1,474 | n/a |
AM0955 # 02 Y:2025 | 02 | 2025 | INSTALL OCCUPANCY SENSORS | $485 | $1,668 | n/a |
AM0955 # 04 Y:2025 | 04 | 2025 | USE SOLAR HEAT TO MAKE ELECTRICTY | $12,041 | $229,320 | n/a |
LS0625 # 01 Y:2025 | 01 | 2025 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $3,054 | $0 | n/a |
LS0625 # 02 Y:2025 | 02 | 2025 | INSTALL OCCUPANCY SENSORS | $2,773 | $625 | n/a |
LS0625 # 03 Y:2025 | 03 | 2025 | CLEAN AND MAINTAIN REFRIGERANT CONDENSERS AND TOWERS | $1,618 | $1,190 | n/a |
LS0625 # 06 Y:2025 | 06 | 2025 | REPLACE HEAT TREATING OVEN WITH MORE EFFICIENT UNIT | $1,754 | $5,000 | n/a |
LS0625 # 05 Y:2025 | 05 | 2025 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,623 | $6,769 | n/a |
LS0625 # 04 Y:2025 | 04 | 2025 | REDUCE HEAT GAIN BY WINDOW TINTING | $1,068 | $1,428 | n/a |
LS0525 # 02 Y:2025 | 02 | 2025 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $2,289 | $175 | n/a |
LS0525 # 01 Y:2025 | 01 | 2025 | CHILL WATER TO THE HIGHEST TEMPERATURE POSSIBLE | $6,053 | $250 | n/a |
LS0525 # 03 Y:2025 | 03 | 2025 | REDUCE HEAT GAIN BY WINDOW TINTING | $9,960 | $1,680 | n/a |