Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
31
matching recommendationsSIC | 86 | Membership Organizations |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UD1094 # 03 Y:2024 | 03 | 2024 | USE DOUBLE OR TRIPLE GLAZED WINDOWS TO MAINTAIN HIGHER RELATIVE HUMIDITY AND TO REDUCE HEAT LOSSES | $342 | $20,000 | n/a |
UD1094 # 02 Y:2024 | 02 | 2024 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $880 | $0 | n/a |
UD1094 # 01 Y:2024 | 01 | 2024 | USE SOLAR HEAT TO MAKE ELECTRICTY | $9,350 | $130,000 | n/a |
UD1091 # 03 Y:2024 | 03 | 2024 | USE DOUBLE OR TRIPLE GLAZED WINDOWS TO MAINTAIN HIGHER RELATIVE HUMIDITY AND TO REDUCE HEAT LOSSES | $70 | $6,000 | n/a |
UD1091 # 01 Y:2024 | 01 | 2024 | USE SOLAR HEAT TO MAKE ELECTRICTY | $793 | $5,200 | n/a |
UD1091 # 02 Y:2024 | 02 | 2024 | USE HEAT PUMP FOR SPACE CONDITIONING | $978 | $30,000 | n/a |
LS0524 # 01 Y:2024 | 01 | 2024 | USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE | $5,077 | $2,040 | n/a |
LS0524 # 02 Y:2024 | 02 | 2024 | INSTALL OCCUPANCY SENSORS | $340 | $200 | n/a |
LS0524 # 03 Y:2024 | 03 | 2024 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $620 | $578 | n/a |
LS0324 # 03 Y:2024 | 03 | 2024 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,954 | $13,620 | Implemented |
LS0324 # 02 Y:2024 | 02 | 2024 | USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE | $12,003 | $1,360 | Implemented |
LS0324 # 01 Y:2024 | 01 | 2024 | INSTALL OCCUPANCY SENSORS | $2,912 | $175 | Implemented |
UD1076 # 04 Y:2024 | 04 | 2024 | USE SOLAR HEAT TO MAKE ELECTRICTY | $29,440 | $362,600 | Not Implemented |
UD1076 # 03 Y:2024 | 03 | 2024 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,098 | $6,750 | Not Implemented |
UD1076 # 02 Y:2024 | 02 | 2024 | SHADE WINDOWS FROM SUMMER SUN | $1,380 | $8,000 | Not Implemented |
UD1076 # 01 Y:2024 | 01 | 2024 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $4,155 | $0 | Not Implemented |
IP7001 # 01 Y:2023 | 01 | 2023 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,404 | $855 | Not Implemented |
IP7001 # 02 Y:2023 | 02 | 2023 | CLOSE HOLES AND OPENINGS IN BUILDING SUCH AS BROKEN WINDOWS | $28 | $45 | Not Implemented |
IP7001 # 03 Y:2023 | 03 | 2023 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $8,873 | $10,560 | Not Implemented |
IP7001 # 04 Y:2023 | 04 | 2023 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $1,900 | $3,380 | Not Implemented |
AM0884 # 02 Y:2023 | 02 | 2023 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $1,250 | $38,000 | n/a |
AM0884 # 03 Y:2023 | 03 | 2023 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $1,819 | $8,400 | n/a |
AM0884 # 01 Y:2023 | 01 | 2023 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,259 | $11,361 | n/a |
AM0872 # 01 Y:2023 | 01 | 2023 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $11,338 | $181,299 | n/a |
AM0872 # 04 Y:2023 | 04 | 2023 | CHILL WATER TO THE HIGHEST TEMPERATURE POSSIBLE | $1,844 | $5,000 | n/a |