IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

147,226

matching recommendations
Reset
ARC 2 ENERGY MANAGEMENT
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
SD0049 # 04 Y:1993 04 1993 INSTALL SPECTRAL REFLECTORS / DELAMP $1,500 $2,520 Implemented
SD0049 # 05 Y:1993 05 1993 INSTALL SET-BACK TIMERS $1,317 $2,120 Implemented
SD0049 # 06 Y:1993 06 1993 USE COOLING AIR WHICH COOLS HOT WORK PIECES FOR SPACE HEATING $3,312 $11,632 Not Implemented
TN0477 # 01 Y:1993 01 1993 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $7,139 $10,080 Implemented
TN0477 # 02 Y:1993 02 1993 USE DEMAND CONTROLLER OR LOAD SHEDDER $3,120 $0 Not Implemented
TN0477 # 03 Y:1993 03 1993 USE SYNTHETIC LUBRICANT $3,013 $1,506 Implemented
TN0477 # 04 Y:1993 04 1993 USE SYNTHETIC LUBRICANT $283 $0 Implemented
AM0176 # 01 Y:1993 01 1993 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $1,710 $400 Implemented
AM0176 # 02 Y:1993 02 1993 REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS $1,925 $135 Implemented
AM0176 # 03 Y:1993 03 1993 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,375 $2,290 Implemented
AM0176 # 04 Y:1993 04 1993 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $550 $0 Not Implemented
AM0177 # 01 Y:1993 01 1993 COMBINE UTILITY METERS $12,900 $40,000 Not Implemented
AM0177 # 02 Y:1993 02 1993 USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE $730 $6,150 Implemented
AM0177 # 03 Y:1993 03 1993 INSTALL SPECTRAL REFLECTORS / DELAMP $1,160 $470 Not Implemented
AM0177 # 04 Y:1993 04 1993 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $190 $570 Implemented
AM0177 # 05 Y:1993 05 1993 APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES $790 $1,000 Implemented
AM0177 # 06 Y:1993 06 1993 TURN OFF EQUIPMENT WHEN NOT IN USE $130 $0 Implemented
CO0270 # 01 Y:1993 01 1993 ESTABLISH EQUIPMENT MAINTENANCE SCHEDULE $2,400 $250 Implemented
CO0270 # 02 Y:1993 02 1993 UTILIZE AN EVAPORATIVE AIR PRE-COOLER OR OTHER HEAT EXCHANGER IN AC SYSTEM $14,790 $16,720 Not Implemented
CO0270 # 03 Y:1993 03 1993 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $2,020 $2,500 Implemented
CO0270 # 04 Y:1993 04 1993 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $1,450 $2,850 Implemented
CO0271 # 01 Y:1993 01 1993 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $34,060 $400 Implemented
CO0271 # 02 Y:1993 02 1993 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $4,640 $400 Implemented
CO0271 # 03 Y:1993 03 1993 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $2,260 $2,500 Implemented
CO0271 # 04 Y:1993 04 1993 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $3,240 $8,000 Not Implemented