Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

143,656

matching recommendations
Reset
ARC 2 ENERGY MANAGEMENT
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
IA0015 # 06 Y:1991 06 1991 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $1,851 $100 Implemented
IA0015 # 07 Y:1991 07 1991 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $3,300 $4,278 Implemented
UF0023 # 01 Y:1992 01 1992 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $812 $947 Implemented
UF0023 # 02 Y:1992 02 1992 INSTALL SPECTRAL REFLECTORS / DELAMP $5,224 $11,820 Not Implemented
UF0023 # 03 Y:1992 03 1992 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $130 $5,005 Implemented
UF0023 # 04 Y:1992 04 1992 USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES $1,460 $4,220 Implemented
UF0023 # 05 Y:1992 05 1992 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $299 $3,700 Implemented
UF0023 # 06 Y:1992 06 1992 USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE $7,776 $30,550 Not Implemented
SD0014 # 01 Y:1992 01 1992 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $1,040 $742 Implemented
SD0014 # 02 Y:1992 02 1992 MINIMIZE BOILER BLOWDOWN WITH BETTER FEEDWATER TREATMENT $914 $1,800 Implemented
SD0014 # 03 Y:1992 03 1992 USE HEAT FROM BOILER BLOWDOWN TO PREHEAT BOILER FEED WATER $71 $1,200 Not Implemented
SD0014 # 04 Y:1992 04 1992 INSTALL SET-BACK TIMERS $7,040 $8,473 Not Implemented
SD0014 # 05 Y:1992 05 1992 KEEP LAMPS AND REFLECTORS CLEAN $16,709 $26,424 Implemented
SD0015 # 01 Y:1992 01 1992 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $312 $567 Not Implemented
SD0015 # 02 Y:1992 02 1992 REPLACE OBSOLETE BURNERS WITH MORE EFFICIENT ONES $1,236 $3,800 Not Implemented
SD0015 # 03 Y:1992 03 1992 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $3,822 $2,000 Not Implemented
SD0015 # 04 Y:1992 04 1992 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $647 $544 Not Implemented
SD0015 # 05 Y:1992 05 1992 INSTALL SET-BACK TIMERS $1,106 $1,650 Not Implemented
SD0015 # 06 Y:1992 06 1992 KEEP LAMPS AND REFLECTORS CLEAN $9,743 $1,657 Not Implemented
GT0458 # 01 Y:1992 01 1992 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $580 $1,740 Implemented
GT0458 # 02 Y:1992 02 1992 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $6,900 $10,600 Implemented
GT0458 # 03 Y:1992 03 1992 IMPROVE LUBRICATION PRACTICES $1,000 $0 Implemented
GT0458 # 04 Y:1992 04 1992 USE OPTIMUM TEMPERATURE $7,600 $0 Implemented
GT0458 # 05 Y:1992 05 1992 USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE $3,200 $700 Implemented
GT0458 # 06 Y:1992 06 1992 USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE $3,200 $10,500 Implemented