Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
143,635
matching recommendationsARC | 2 | ENERGY MANAGEMENT |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
MA0232 # 01 Y:1992 | 01 | 1992 | RE-USE OR RECYCLE HOT OR COLD PROCESS EXHAUST AIR | $31,842 | $90,600 | Not Implemented |
MA0232 # 02 Y:1992 | 02 | 1992 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $61,173 | $70,000 | Not Implemented |
MA0232 # 03 Y:1992 | 03 | 1992 | REPAIR OR REPLACE STEAM TRAPS | $2,293 | $2 | Implemented |
MA0232 # 04 Y:1992 | 04 | 1992 | CENTRALIZE CONTROL OF EXHAUST FANS TO ENSURE THEIR SHUTDOWN, OR ESTABLISH PROGRAM TO ENSURE MANUAL SHUTDOWN | $5,067 | $0 | Implemented |
MA0232 # 05 Y:1992 | 05 | 1992 | INCREASE AMOUNT OF CONDENSATE RETURNED | $884 | $150 | Implemented |
MA0233 # 01 Y:1992 | 01 | 1992 | USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING | $28,770 | $2,000 | Implemented |
MA0233 # 02 Y:1992 | 02 | 1992 | CHILL WATER TO THE HIGHEST TEMPERATURE POSSIBLE | $4,263 | $0 | Not Implemented |
MA0233 # 03 Y:1992 | 03 | 1992 | INSULATE BARE EQUIPMENT | $10,672 | $12,412 | Implemented |
MA0233 # 04 Y:1992 | 04 | 1992 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $7,341 | $14,210 | Implemented |
MA0233 # 05 Y:1992 | 05 | 1992 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,334 | $8,000 | Implemented |
MA0233 # 06 Y:1992 | 06 | 1992 | SUBSTITUTE HOT PROCESS FLUIDS FOR STEAM | $2,393 | $10,000 | Not Implemented |
MA0233 # 07 Y:1992 | 07 | 1992 | IMPROVE LUBRICATION PRACTICES | $1,170 | $0 | Implemented |
MA0234 # 01 Y:1992 | 01 | 1992 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $95,700 | $153,525 | Implemented |
MA0234 # 02 Y:1992 | 02 | 1992 | RE-USE OR RECYCLE HOT OR COLD PROCESS EXHAUST AIR | $38,424 | $77,755 | Not Implemented |
MA0234 # 03 Y:1992 | 03 | 1992 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $13,505 | $24,600 | Implemented |
MA0234 # 04 Y:1992 | 04 | 1992 | INSTALL / REPAIR INSULATION ON STEAM LINES | $9,100 | $3,720 | Implemented |
MA0234 # 05 Y:1992 | 05 | 1992 | DIRECT WARMEST AIR TO COMBUSTION INTAKE | $2,845 | $4,162 | Not Implemented |
MA0234 # 06 Y:1992 | 06 | 1992 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $562 | $0 | Not Implemented |
UF0020 # 01 Y:1992 | 01 | 1992 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,439 | $5,421 | Not Implemented |
UF0020 # 02 Y:1992 | 02 | 1992 | INSTALL SPECTRAL REFLECTORS / DELAMP | $28,591 | $9,720 | Not Implemented |
UF0020 # 03 Y:1992 | 03 | 1992 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $94 | $643 | Not Implemented |
UF0020 # 04 Y:1992 | 04 | 1992 | USE PROPERLY DESIGNED AND SIZED HVAC EQUIPMENT | $1,160 | $1,320 | Implemented |
UF0020 # 05 Y:1992 | 05 | 1992 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $2,332 | $16,490 | Implemented |
UF0021 # 01 Y:1992 | 01 | 1992 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $8,886 | $7,727 | Not Implemented |
UF0021 # 02 Y:1992 | 02 | 1992 | INSTALL SPECTRAL REFLECTORS / DELAMP | $15,608 | $19,830 | Not Implemented |