Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
47,742
matching recommendationsARC | 2.7 | Building and Grounds |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
CO0153 # 05 Y:1989 | 05 | 1989 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $812 | $186 | Not Implemented |
GT0378 # 01 Y:1989 | 01 | 1989 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $270 | $722 | Implemented |
GT0378 # 04 Y:1989 | 04 | 1989 | UTILIZE SENSORS CONTROLLING ROOF AND WALL OPENINGS | $65 | $40 | Implemented |
GT0379 # 01 Y:1989 | 01 | 1989 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $6,310 | $13,690 | Not Implemented |
GT0380 # 01 Y:1989 | 01 | 1989 | INSTALL TIMERS AND/OR THERMOSTATS | $7,220 | $18,000 | Implemented |
GT0380 # 04 Y:1989 | 04 | 1989 | KEEP LAMPS AND REFLECTORS CLEAN | $3,750 | $14,410 | Not Implemented |
GT0380 # 07 Y:1989 | 07 | 1989 | USE DIRECT AIR SUPPLY TO EXHAUST HOODS | $3,560 | $4,000 | Implemented |
GT0380 # 08 Y:1989 | 08 | 1989 | USE RADIANT HEATER FOR SPOT HEATING | $3,840 | $19,500 | Implemented |
TN0369 # 02 Y:1989 | 02 | 1989 | KEEP LAMPS AND REFLECTORS CLEAN | $16,115 | $44,100 | Not Implemented |
TN0369 # 10 Y:1989 | 10 | 1989 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,943 | $450 | Implemented |
TN0372 # 01 Y:1989 | 01 | 1989 | USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE | $46,225 | $71,400 | Implemented |
TN0372 # 05 Y:1989 | 05 | 1989 | INSTALL TIMERS AND/OR THERMOSTATS | $1,716 | $280 | Implemented |
TN0372 # 07 Y:1989 | 07 | 1989 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $282 | $0 | Not Implemented |
TN0373 # 02 Y:1989 | 02 | 1989 | USE RADIANT HEATER FOR SPOT HEATING | $7,050 | $11,350 | Implemented |
TN0373 # 03 Y:1989 | 03 | 1989 | KEEP LAMPS AND REFLECTORS CLEAN | $8,465 | $12,145 | Not Implemented |
TN0373 # 06 Y:1989 | 06 | 1989 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $5,599 | $1,800 | Implemented |
RU0059 # 03 Y:1989 | 03 | 1989 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $11,797 | $16,740 | Not Implemented |
RU0059 # 05 Y:1989 | 05 | 1989 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,490 | $479 | Not Implemented |
RU0061 # 01 Y:1989 | 01 | 1989 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $2,588 | $2,880 | Implemented |
RU0061 # 02 Y:1989 | 02 | 1989 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $785 | $203 | Not Implemented |
RU0061 # 03 Y:1989 | 03 | 1989 | CLOSE HOLES AND OPENINGS IN BUILDING SUCH AS BROKEN WINDOWS | $1,320 | $0 | Not Implemented |
UD0293 # 04 Y:1989 | 04 | 1989 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $498 | $39 | Not Implemented |
UD0294 # 02 Y:1989 | 02 | 1989 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,945 | $693 | Not Implemented |
UD0294 # 03 Y:1989 | 03 | 1989 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,552 | $0 | Not Implemented |
UD0295 # 03 Y:1989 | 03 | 1989 | USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE | $1,900 | $300 | Not Implemented |