Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
5,456
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
CO0165 # 08 Y:1989 | 08 | 1989 | REDUCE VENTILATION AIR | $710 | $450 | Implemented |
CO0165 # 09 Y:1989 | 09 | 1989 | USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE | $418 | $300 | Implemented |
CO0166 # 01 Y:1989 | 01 | 1989 | APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES | $4,860 | $250 | Implemented |
CO0166 # 02 Y:1989 | 02 | 1989 | OPTIMIZE PLANT POWER FACTOR | $3,760 | $3,900 | Implemented |
CO0166 # 03 Y:1989 | 03 | 1989 | INSTALL AUTOMATIC STACK DAMPER | $2,050 | $4,000 | Implemented |
CO0166 # 04 Y:1989 | 04 | 1989 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $1,280 | $4,130 | Not Implemented |
CO0166 # 05 Y:1989 | 05 | 1989 | USE SEPARATE SWITCHES ON PERIMETER LIGHTING WHICH MAY BE TURNED OFF WHEN NATURAL LIGHT IS AVAILABLE | $800 | $600 | Implemented |
CO0166 # 06 Y:1989 | 06 | 1989 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $440 | $200 | Not Implemented |
CO0166 # 07 Y:1989 | 07 | 1989 | MINIMIZE CONDENSER COOLING WATER TEMPERATURE | $430 | $100 | Implemented |
CO0167 # 01 Y:1989 | 01 | 1989 | OPTIMIZE PLANT POWER FACTOR | $6,740 | $6,800 | Implemented |
CO0167 # 02 Y:1989 | 02 | 1989 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,010 | $150 | Implemented |
CO0167 # 03 Y:1989 | 03 | 1989 | RECOVER WASTE HEAT FROM EQUIPMENT | $1,800 | $2,500 | Not Implemented |
CO0167 # 04 Y:1989 | 04 | 1989 | INSTALL TIMERS AND/OR THERMOSTATS | $1,345 | $1,000 | Not Implemented |
CO0167 # 05 Y:1989 | 05 | 1989 | USE DIRECT AIR SUPPLY TO EXHAUST HOODS | $1,200 | $1,900 | Not Implemented |
CO0167 # 06 Y:1989 | 06 | 1989 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $455 | $335 | Implemented |
CO0167 # 07 Y:1989 | 07 | 1989 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $105 | $315 | Implemented |
CO0167 # 08 Y:1989 | 08 | 1989 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $870 | $200 | Implemented |
CO0167 # 09 Y:1989 | 09 | 1989 | INSULATE BARE EQUIPMENT | $360 | $290 | Implemented |
CO0168 # 01 Y:1989 | 01 | 1989 | APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES | $1,360 | $250 | Implemented |
CO0168 # 02 Y:1989 | 02 | 1989 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $2,015 | $4,600 | Not Implemented |
CO0168 # 03 Y:1989 | 03 | 1989 | COVER OPEN TANKS | $1,600 | $400 | Implemented |
CO0168 # 04 Y:1989 | 04 | 1989 | INSULATE BARE EQUIPMENT | $590 | $420 | Implemented |
CO0168 # 05 Y:1989 | 05 | 1989 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $955 | $425 | Implemented |
CO0168 # 06 Y:1989 | 06 | 1989 | INSTALL SET-BACK TIMERS | $604 | $1,600 | Not Implemented |
CO0168 # 07 Y:1989 | 07 | 1989 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $550 | $300 | Implemented |