Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

5,456

matching recommendations
Reset
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
CO0041 # 02 Y:1985 02 1985 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $359 $2,000 Not Implemented
CO0041 # 03 Y:1985 03 1985 TURN OFF EQUIPMENT WHEN NOT IN USE $125 $200 Implemented
CO0041 # 04 Y:1985 04 1985 INCREASE AMOUNT OF CONDENSATE RETURNED $139 $180 Implemented
CO0041 # 05 Y:1985 05 1985 AIR CONDITION ONLY SPACE NECESSARY $1,164 $2,000 Implemented
CO0041 # 06 Y:1985 06 1985 INSTALL / REPAIR INSULATION ON STEAM LINES $838 $95 Implemented
CO0041 # 07 Y:1985 07 1985 AIR CONDITION ONLY SPACE NECESSARY $2,136 $225 Implemented
CO0041 # 08 Y:1985 08 1985 AIR CONDITION ONLY SPACE NECESSARY $3,403 $84 Not Implemented
CO0041 # 09 Y:1985 09 1985 INSTALL TIMERS AND/OR THERMOSTATS $599 $400 Implemented
CO0041 # 10 Y:1985 10 1985 USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE $206 $258 Not Implemented
CO0041 # 11 Y:1985 11 1985 USE FLUE GASES IN RADIANT HEATER FOR SPACE HEATING, OVENS, ETC $924 $5,000 Not Implemented
CO0041 # 12 Y:1985 12 1985 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS $1,701 $0 Implemented
CO0041 # 13 Y:1985 13 1985 REDESIGN PROCESS $1,481 $1,140 Not Implemented
CO0041 # 14 Y:1985 14 1985 IMPROVE LUBRICATION PRACTICES $882 $100 Not Implemented
CO0042 # 01 Y:1985 01 1985 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS $5,853 $645 Implemented
CO0042 # 02 Y:1985 02 1985 TURN OFF EQUIPMENT WHEN NOT IN USE $6,858 $450 Not Implemented
CO0042 # 03 Y:1985 03 1985 TURN OFF EQUIPMENT WHEN NOT IN USE $91 $100 Not Implemented
CO0042 # 04 Y:1985 04 1985 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS $5,923 $600 Not Implemented
CO0042 # 05 Y:1985 05 1985 RECOVER WASTE HEAT FROM EQUIPMENT $283 $200 Implemented
CO0042 # 06 Y:1985 06 1985 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $69 $100 Not Implemented
CO0042 # 07 Y:1985 07 1985 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $2,926 $200 Implemented
CO0042 # 08 Y:1985 08 1985 USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE $1,256 $2,000 Not Implemented
CO0042 # 09 Y:1985 09 1985 USE FLUE GASES IN RADIANT HEATER FOR SPACE HEATING, OVENS, ETC $1,421 $5,500 Not Implemented
CO0042 # 10 Y:1985 10 1985 COVER OPEN TANKS $1,052 $234 Not Implemented
CO0042 # 11 Y:1985 11 1985 INSTALL TIMERS AND/OR THERMOSTATS $18,823 $500 Implemented
CO0042 # 12 Y:1985 12 1985 INSTALL STORM WINDOWS AND DOORS $7,925 $4,000 Not Implemented