Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
2,349
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
IA0049 # 03 Y:1993 | 03 | 1993 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $5,833 | $2,623 | Implemented |
IA0049 # 04 Y:1993 | 04 | 1993 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,760 | $500 | Implemented |
IA0048 # 01 Y:1993 | 01 | 1993 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $10,403 | $500 | Implemented |
IA0048 # 05 Y:1993 | 05 | 1993 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,254 | $272 | Implemented |
IA0048 # 06 Y:1993 | 06 | 1993 | INSULATE BARE EQUIPMENT | $25 | $43 | Implemented |
IA0047 # 01 Y:1993 | 01 | 1993 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,116 | $2,000 | Implemented |
IA0047 # 02 Y:1993 | 02 | 1993 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $71 | $50 | Implemented |
IA0047 # 03 Y:1993 | 03 | 1993 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,414 | $441 | Implemented |
IA0047 # 04 Y:1993 | 04 | 1993 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $574 | $112 | Implemented |
IA0044 # 02 Y:1993 | 02 | 1993 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $4,209 | $630 | Implemented |
IA0044 # 03 Y:1993 | 03 | 1993 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,777 | $5,800 | Implemented |
IA0044 # 05 Y:1993 | 05 | 1993 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $739 | $73 | Implemented |
IA0044 # 06 Y:1993 | 06 | 1993 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $125 | $240 | Implemented |
IA0043 # 01 Y:1993 | 01 | 1993 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,522 | $100 | Implemented |
IA0043 # 04 Y:1993 | 04 | 1993 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $4,409 | $6,400 | Implemented |
IA0043 # 05 Y:1993 | 05 | 1993 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $394 | $1,752 | Implemented |
IA0043 # 07 Y:1993 | 07 | 1993 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $196 | $321 | Implemented |
IA0043 # 08 Y:1993 | 08 | 1993 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $320 | $280 | Implemented |
IA0045 # 01 Y:1993 | 01 | 1993 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $15,690 | $660 | Implemented |
IA0045 # 03 Y:1993 | 03 | 1993 | USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE | $4,196 | $2,893 | Implemented |
IA0046 # 01 Y:1993 | 01 | 1993 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,020 | $50 | Implemented |
IA0046 # 02 Y:1993 | 02 | 1993 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,060 | $150 | Implemented |
IA0046 # 04 Y:1993 | 04 | 1993 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $942 | $125 | Implemented |
IA0046 # 05 Y:1993 | 05 | 1993 | REPLACE BROKEN WINDOWS AND/OR WINDOW SASH | $22 | $20 | Implemented |
IA0038 # 03 Y:1992 | 03 | 1992 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $6,907 | $150 | Implemented |