Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
2,813
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
KU0065 # 03 Y:1982 | 03 | 1982 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $3,815 | $0 | Implemented |
KU0065 # 04 Y:1982 | 04 | 1982 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $441 | $0 | Not Implemented |
KU0065 # 05 Y:1982 | 05 | 1982 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $459 | $1,000 | Not Implemented |
KU0065 # 06 Y:1982 | 06 | 1982 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $290 | $0 | Not Implemented |
KU0065 # 07 Y:1982 | 07 | 1982 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $214 | $59 | Not Implemented |
KU0065 # 08 Y:1982 | 08 | 1982 | INSTALL AUTOMATIC STACK DAMPER | $326 | $528 | Not Implemented |
KU0056 # 01 Y:1982 | 01 | 1982 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $10,692 | $2,784 | Implemented |
KU0056 # 02 Y:1982 | 02 | 1982 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $17,863 | $2,000 | Implemented |
KU0056 # 03 Y:1982 | 03 | 1982 | CONVERT COMBUSTION EQUIPMENT TO BURN NATURAL GAS | $16,065 | $20,000 | Implemented |
KU0056 # 04 Y:1982 | 04 | 1982 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $14,900 | $450 | Not Implemented |
KU0056 # 05 Y:1982 | 05 | 1982 | USE HOT PROCESS FLUIDS TO PREHEAT INCOMING PROCESS FLUIDS | $10,800 | $20,000 | Implemented |
KU0056 # 06 Y:1982 | 06 | 1982 | INSTALL / REPAIR INSULATION ON STEAM LINES | $5,190 | $1,724 | Implemented |
KU0056 # 07 Y:1982 | 07 | 1982 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $4,225 | $1,000 | Implemented |
KU0056 # 08 Y:1982 | 08 | 1982 | RECOVER WASTE HEAT FROM EQUIPMENT | $3,030 | $2,940 | Implemented |
KU0057 # 01 Y:1982 | 01 | 1982 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,441 | $888 | Not Implemented |
KU0057 # 02 Y:1982 | 02 | 1982 | USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE | $1,030 | $2,800 | Implemented |
KU0057 # 03 Y:1982 | 03 | 1982 | INSTALL TIMERS AND/OR THERMOSTATS | $545 | $300 | Implemented |
KU0057 # 04 Y:1982 | 04 | 1982 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $418 | $438 | Implemented |
KU0057 # 05 Y:1982 | 05 | 1982 | CHECK FOR ACCURACY OF UTILITY / POWER METERS | $296 | $0 | Implemented |
KU0057 # 06 Y:1982 | 06 | 1982 | INSTALL AUTOMATIC STACK DAMPER | $135 | $275 | Implemented |
KU0057 # 07 Y:1982 | 07 | 1982 | REDUCE HOT WATER TEMPERATURE TO THE MINIMUM REQUIRED | $939 | $0 | Not Implemented |
KU0057 # 08 Y:1982 | 08 | 1982 | INSULATE BARE EQUIPMENT | $604 | $59 | Implemented |
KU0058 # 01 Y:1982 | 01 | 1982 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,433 | $1,567 | Not Implemented |
KU0058 # 02 Y:1982 | 02 | 1982 | RECOVER WASTE HEAT FROM EQUIPMENT | $14,678 | $24,000 | Implemented |
KU0058 # 03 Y:1982 | 03 | 1982 | REPLACE GASOLINE WITH DIESEL, LPG, OR NATURAL GAS | $10,505 | $27,500 | Not Implemented |