IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

2,614

matching recommendations
Reset
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
MS0154 # 05 Y:2000 05 2000 AVOID INTRODUCING HOT, HUMID, OR DIRTY AIR INTO HVAC SYSTEM $1,134 $361 Not Implemented
MS0154 # 06 Y:2000 06 2000 $880 $50 Implemented
MS0153 # 01 Y:2000 01 2000 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $3,745 $1,384 Implemented
MS0153 # 02 Y:2000 02 2000 OPTIMIZE PLANT POWER FACTOR $4,678 $4,725 Implemented
MS0153 # 03 Y:2000 03 2000 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $1,254 $322 Not Implemented
MS0153 # 04 Y:2000 04 2000 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $2,107 $1,552 Implemented
MS0153 # 05 Y:2000 05 2000 INSTALL TIMERS AND/OR THERMOSTATS $9,517 $3,600 Not Implemented
MS0153 # 06 Y:2000 06 2000 INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT $16,003 $27,300 Not Implemented
MS0153 # 07 Y:2000 07 2000 USE RE-USABLE FILTERS $735 $560 Not Implemented
MS0153 # 08 Y:2000 08 2000 CONVERT TO HIGH VOLUME LOW PRESSURE (HVLP) PAINT GUNS $10,573 $3,540 Implemented
MS0152 # 01 Y:2000 01 2000 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $331 $136 Not Implemented
MS0152 # 02 Y:2000 02 2000 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $8,518 $457 Implemented
MS0152 # 03 Y:2000 03 2000 RECOVER WASTE HEAT FROM EQUIPMENT $3,651 $3,747 Not Implemented
MS0152 # 04 Y:2000 04 2000 INSTALL TIMERS AND/OR THERMOSTATS $3,911 $2,652 Implemented
MS0152 # 05 Y:2000 05 2000 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $1,407 $4,000 Not Implemented
MS0152 # 06 Y:2000 06 2000 BURN WASTE OIL FOR HEAT $432 $1,974 Not Implemented
MS0152 # 07 Y:2000 07 2000 USE CLOSED CYCLE PROCESS TO MINIMIZE WASTE WATER PRODUCTION $8,948 $4,500 Not Implemented
MS0146 # 01 Y:1999 01 1999 OPTIMIZE PLANT POWER FACTOR $2,236 $2,610 Not Implemented
MS0146 # 02 Y:1999 02 1999 INSTALL TIMERS AND/OR THERMOSTATS $50 $119 Implemented
MS0146 # 03 Y:1999 03 1999 USE PHOTOCELL CONTROLS $276 $222 Not Implemented
MS0146 # 04 Y:1999 04 1999 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $635 $89 Not Implemented
MS0146 # 05 Y:1999 05 1999 INSTALL OCCUPANCY SENSORS $192 $346 Not Implemented
MS0146 # 06 Y:1999 06 1999 INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT $4,736 $4,200 Not Implemented
MS0146 # 07 Y:1999 07 1999 INSULATE BARE EQUIPMENT $2,189 $2,446 Not Implemented
MS0146 # 08 Y:1999 08 1999 USE RE-USABLE FILTERS $4,800 $648 Implemented