Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
5,176
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
NC0006 # 07 Y:1993 | 07 | 1993 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $3,538 | $6,000 | Not Implemented |
NC0002 # 01 Y:1993 | 01 | 1993 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $566 | $522 | Implemented |
NC0002 # 02 Y:1993 | 02 | 1993 | INSTALL SPECTRAL REFLECTORS / DELAMP | $3,351 | $120 | Not Implemented |
NC0002 # 03 Y:1993 | 03 | 1993 | REMOVE OR CLOSE OFF UNNEEDED COMPRESSED AIR LINES | $1,991 | $1,209 | Implemented |
NC0002 # 04 Y:1993 | 04 | 1993 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,206 | $100 | Implemented |
NC0002 # 05 Y:1993 | 05 | 1993 | INSTALL SKYLIGHTS | $5,957 | $9,715 | Not Implemented |
NC0002 # 06 Y:1993 | 06 | 1993 | INSULATE GLAZING, WALLS, CEILINGS, AND ROOFS | $17,784 | $39,880 | Not Implemented |
NC0003 # 01 Y:1993 | 01 | 1993 | USE PHOTOCELL CONTROLS | $381 | $159 | Implemented |
NC0003 # 02 Y:1993 | 02 | 1993 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $648 | $360 | Implemented |
NC0003 # 03 Y:1993 | 03 | 1993 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $5,625 | $300 | Implemented |
NC0003 # 04 Y:1993 | 04 | 1993 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $2,844 | $1,000 | Implemented |
NC0003 # 05 Y:1993 | 05 | 1993 | RECOVER WASTE HEAT FROM EQUIPMENT | $6,594 | $6,000 | Implemented |
NC0003 # 06 Y:1993 | 06 | 1993 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $13,205 | $31,000 | Not Implemented |
NC0003 # 07 Y:1993 | 07 | 1993 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $307 | $650 | Implemented |
NC0004 # 01 Y:1993 | 01 | 1993 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $6,514 | $1,222 | Implemented |
NC0004 # 02 Y:1993 | 02 | 1993 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,054 | $690 | Implemented |
NC0004 # 03 Y:1993 | 03 | 1993 | RECOVER AND REUSE COOLING WATER | $834 | $500 | Not Implemented |
NC0004 # 04 Y:1993 | 04 | 1993 | RECOVER WASTE HEAT FROM EQUIPMENT | $26,384 | $1,500 | Not Implemented |
NC0004 # 05 Y:1993 | 05 | 1993 | SIZE ELECTRIC MOTORS FOR PEAK OPERATING EFFICIENCY | $1,143 | $1,100 | Not Implemented |
NC0004 # 06 Y:1993 | 06 | 1993 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $1,494 | $4,500 | Not Implemented |
NC0001 # 01 Y:1993 | 01 | 1993 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,139 | $1,577 | Not Implemented |
NC0001 # 02 Y:1993 | 02 | 1993 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $3,100 | $500 | Implemented |
NC0001 # 03 Y:1993 | 03 | 1993 | CLOSE HOLES AND OPENINGS IN BUILDING SUCH AS BROKEN WINDOWS | $745 | $300 | Implemented |
NC0001 # 04 Y:1993 | 04 | 1993 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $588 | $10 | Implemented |
NC0001 # 05 Y:1993 | 05 | 1993 | UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED | $162 | $100 | Implemented |