Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
4,631
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UD0033 # 03 Y:1982 | 03 | 1982 | REDUCE HOT WATER TEMPERATURE TO THE MINIMUM REQUIRED | $84 | $0 | Implemented |
UD0033 # 04 Y:1982 | 04 | 1982 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $872 | $250 | Implemented |
UD0030 # 01 Y:1982 | 01 | 1982 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $1,014 | $0 | Implemented |
UD0030 # 03 Y:1982 | 03 | 1982 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $995 | $210 | Implemented |
UD0030 # 05 Y:1982 | 05 | 1982 | REPLACE BROKEN WINDOWS AND/OR WINDOW SASH | $4,094 | $3,008 | Implemented |
UD0025 # 03 Y:1982 | 03 | 1982 | REDUCE HOT WATER TEMPERATURE TO THE MINIMUM REQUIRED | $162 | $0 | Implemented |
UD0026 # 03 Y:1982 | 03 | 1982 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $297 | $48 | Implemented |
UD0028 # 01 Y:1982 | 01 | 1982 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $828 | $482 | Implemented |
UD0028 # 02 Y:1982 | 02 | 1982 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $7,052 | $0 | Implemented |
UD0028 # 04 Y:1982 | 04 | 1982 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $516 | $250 | Implemented |
UD0017 # 01 Y:1982 | 01 | 1982 | USE OPTIMUM THICKNESS INSULATION | $1,212 | $0 | Implemented |
UD0017 # 02 Y:1982 | 02 | 1982 | USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE | $1,596 | $25,000 | Implemented |
UD0017 # 03 Y:1982 | 03 | 1982 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $7,526 | $776 | Implemented |
UD0019 # 01 Y:1982 | 01 | 1982 | USE SEPARATE SWITCHES ON PERIMETER LIGHTING WHICH MAY BE TURNED OFF WHEN NATURAL LIGHT IS AVAILABLE | $550 | $150 | Implemented |
UD0019 # 02 Y:1982 | 02 | 1982 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $3,596 | $5,400 | Implemented |
UD0020 # 01 Y:1982 | 01 | 1982 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $20,824 | $30,000 | Implemented |
UD0020 # 02 Y:1982 | 02 | 1982 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $430 | $300 | Implemented |
UD0021 # 01 Y:1982 | 01 | 1982 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $1,609 | $576 | Implemented |
UD0021 # 02 Y:1982 | 02 | 1982 | INSTALL STORM WINDOWS AND DOORS | $330 | $314 | Implemented |
UD0022 # 01 Y:1982 | 01 | 1982 | USE SEPARATE SWITCHES ON PERIMETER LIGHTING WHICH MAY BE TURNED OFF WHEN NATURAL LIGHT IS AVAILABLE | $1,141 | $45 | Implemented |
UD0022 # 03 Y:1982 | 03 | 1982 | CONVERT COMBUSTION EQUIPMENT TO BURN NATURAL GAS | $39,185 | $33,000 | Implemented |
UD0023 # 01 Y:1982 | 01 | 1982 | USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE | $7,104 | $6,705 | Implemented |
UD0023 # 02 Y:1982 | 02 | 1982 | USE SEPARATE SWITCHES ON PERIMETER LIGHTING WHICH MAY BE TURNED OFF WHEN NATURAL LIGHT IS AVAILABLE | $14,006 | $3,864 | Implemented |
UD0023 # 03 Y:1982 | 03 | 1982 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $3,266 | $300 | Implemented |
UD0018 # 03 Y:1981 | 03 | 1981 | USE OPTIMUM THICKNESS INSULATION | $445 | $0 | Implemented |