Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
1,271
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
WV0397 # 10 Y:2009 | 10 | 2009 | REPAIR OR REPLACE STEAM TRAPS | $7,120 | $5,500 | Implemented |
WV0397 # 11 Y:2009 | 11 | 2009 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $6,792 | $19,960 | Implemented |
WV0396 # 04 Y:2009 | 04 | 2009 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $69,637 | $1,000 | Implemented |
WV0396 # 05 Y:2009 | 05 | 2009 | INSTALL / REPAIR INSULATION ON STEAM LINES | $10,128 | $3,390 | Implemented |
WV0396 # 06 Y:2009 | 06 | 2009 | DEVELOP A REPAIR/REPLACE POLICY | $9,954 | $1,094 | Implemented |
WV0396 # 08 Y:2009 | 08 | 2009 | ESTABLISH A PREDICTIVE MAINTENANCE PROGRAM | $8,609 | $1,000 | Implemented |
WV0396 # 10 Y:2009 | 10 | 2009 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,796 | $263 | Implemented |
WV0396 # 12 Y:2009 | 12 | 2009 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $846 | $50 | Implemented |
WV0396 # 13 Y:2009 | 13 | 2009 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $829 | $0 | Implemented |
WV0396 # 14 Y:2009 | 14 | 2009 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $781 | $575 | Implemented |
WV0394 # 02 Y:2009 | 02 | 2009 | USE "HEAT WHEEL" OR OTHER HEAT EXCHANGER TO CROSS-EXCHANGE BUILDING EXHAUST AIR WITH MAKE-UP AIR | $22,727 | $50,200 | Implemented |
WV0394 # 04 Y:2009 | 04 | 2009 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $15,978 | $19,253 | Implemented |
WV0394 # 06 Y:2009 | 06 | 2009 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $5,269 | $600 | Implemented |
WV0394 # 08 Y:2009 | 08 | 2009 | DEVELOP A REPAIR/REPLACE POLICY | $3,395 | $678 | Implemented |
WV0394 # 09 Y:2009 | 09 | 2009 | ESTABLISH A PREDICTIVE MAINTENANCE PROGRAM | $2,940 | $1,000 | Implemented |
WV0394 # 11 Y:2009 | 11 | 2009 | INSTALL / REPAIR INSULATION ON STEAM LINES | $1,448 | $619 | Implemented |
WV0394 # 13 Y:2009 | 13 | 2009 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $998 | $0 | Implemented |
WV0394 # 15 Y:2009 | 15 | 2009 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $335 | $158 | Implemented |
WV0372 # 02 Y:2008 | 02 | 2008 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $13,813 | $2,000 | Implemented |
WV0372 # 03 Y:2008 | 03 | 2008 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $10,188 | $511 | Implemented |
WV0372 # 05 Y:2008 | 05 | 2008 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $5,593 | $8,011 | Implemented |
WV0372 # 06 Y:2008 | 06 | 2008 | ESTABLISH A PREDICTIVE MAINTENANCE PROGRAM | $5,074 | $4,500 | Implemented |
WV0372 # 07 Y:2008 | 07 | 2008 | DEVELOP A REPAIR/REPLACE POLICY | $3,550 | $890 | Implemented |
WV0372 # 09 Y:2008 | 09 | 2008 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,523 | $0 | Implemented |
WV0371 # 01 Y:2008 | 01 | 2008 | ADJUST BURNERS FOR EFFICIENT OPERATION | $284,875 | $10,157 | Implemented |