Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

835

matching recommendations
Reset
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
DS0009 # 02 Y:1994 02 1994 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $3,241 $5,955 Implemented
DS0008 # 01 Y:1994 01 1994 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $7,313 $9,699 Implemented
DS0007 # 03 Y:1994 03 1994 INSULATE BARE EQUIPMENT $6,957 $1,902 Implemented
DS0005 # 01 Y:1994 01 1994 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $986 $3,642 Implemented
DS0005 # 04 Y:1994 04 1994 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $329 $132 Implemented
DS0005 # 05 Y:1994 05 1994 RECOVER WASTE HEAT FROM EQUIPMENT $1,476 $1,350 Implemented
DS0005 # 10 Y:1994 10 1994 REPLACE GASOLINE WITH DIESEL, LPG, OR NATURAL GAS $1,640 $3,800 Implemented
DS0004 # 01 Y:1994 01 1994 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,193 $1,791 Implemented
DS0004 # 03 Y:1994 03 1994 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $415 $144 Implemented
DS0004 # 04 Y:1994 04 1994 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $1,246 $3,479 Implemented
DS0004 # 05 Y:1994 05 1994 TURN OFF EQUIPMENT WHEN NOT IN USE $1,636 $400 Implemented
DS0004 # 09 Y:1994 09 1994 UTILIZE OUTSIDE AIR INSTEAD OF CONDITIONED AIR FOR DRYING $8,212 $16,424 Implemented
DS0003 # 04 Y:1994 04 1994 INSTALL / REPAIR INSULATION ON STEAM LINES $3,195 $285 Implemented
DS0003 # 05 Y:1994 05 1994 REPAIR AND ELIMINATE STEAM LEAKS $596 $400 Implemented
DS0003 # 08 Y:1994 08 1994 SHUT OFF COOLING IF COLD OUTSIDE AIR WILL COOL PROCESS $7,726 $26,660 Implemented
IA0079 # 04 Y:1994 04 1994 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $1,195 $136 Implemented
IA0079 # 05 Y:1994 05 1994 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $852 $45 Implemented
IA0061 # 04 Y:1993 04 1993 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $3,928 $1,939 Implemented
IA0061 # 07 Y:1993 07 1993 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $110 $120 Implemented
IA0059 # 01 Y:1993 01 1993 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $10,092 $300 Implemented
IA0059 # 02 Y:1993 02 1993 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $1,455 $0 Implemented
IA0059 # 03 Y:1993 03 1993 USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE $8,568 $27,000 Implemented
IA0059 # 04 Y:1993 04 1993 USE DEMAND CONTROLLER OR LOAD SHEDDER $8,390 $5,850 Implemented
IA0059 # 05 Y:1993 05 1993 RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS $264 $0 Implemented
IA0059 # 07 Y:1993 07 1993 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $1,828 $1,740 Implemented