IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

3,263

matching recommendations
Reset
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
LS1523 # 05 Y:2023 05 2023 USE SOLAR HEAT TO MAKE ELECTRICTY $6,524 $34,650 Not Implemented
LT8377 # 01 Y:2023 01 2023 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $20,663 $39,769 n/a
LT8377 # 02 Y:2023 02 2023 USE PHOTOCELL CONTROLS $1,150 $917 n/a
LT8377 # 03 Y:2023 03 2023 AVOID INTRODUCING HOT, HUMID, OR DIRTY AIR INTO HVAC SYSTEM $4,486 $0 n/a
LT8377 # 04 Y:2023 04 2023 MINIMIZE USE OF OUTSIDE MAKE-UP AIR FOR VENTILATION EXCEPT WHEN USED FOR ECONOMIZER CYCLE $43,128 $221,785 n/a
LT8377 # 05 Y:2023 05 2023 INSULATE GLAZING, WALLS, CEILINGS, AND ROOFS $5,113 $47,950 n/a
LT8378 # 01 Y:2023 01 2023 INSTALL TIMERS AND/OR THERMOSTATS $11,552 $30,450 n/a
LT8378 # 02 Y:2023 02 2023 REPLACE HEAT TREATING OVEN WITH MORE EFFICIENT UNIT $3,145 $2,591 n/a
LT8378 # 03 Y:2023 03 2023 MINIMIZE USE OF OUTSIDE MAKE-UP AIR FOR VENTILATION EXCEPT WHEN USED FOR ECONOMIZER CYCLE $11,415 $0 n/a
LT8378 # 04 Y:2023 04 2023 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $869 $864 n/a
LT8378 # 05 Y:2023 05 2023 INSTALL OCCUPANCY SENSORS $2,353 $10,050 n/a
LT8380 # 01 Y:2023 01 2023 TURN OFF EQUIPMENT WHEN NOT IN USE $2,583 $2,922 n/a
LT8380 # 02 Y:2023 02 2023 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $916 $843 n/a
LT8380 # 03 Y:2023 03 2023 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $2,502 $255 n/a
LT8380 # 04 Y:2023 04 2023 REPLACE EXISTING EQUIPMENT WITH MORE SUITABLE SUBSTITUTES $17,700 $1,500 n/a
LS1423 # 01 Y:2023 01 2023 MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED $1,322 $0 Implemented
LS1423 # 02 Y:2023 02 2023 INSTALL TIMERS AND/OR THERMOSTATS $6,320 $540 Not Implemented
LS1423 # 03 Y:2023 03 2023 REDUCE HEAT GAIN BY WINDOW TINTING $5,029 $1,176 Not Implemented
LS1423 # 04 Y:2023 04 2023 KEEP DOORS AND WINDOWS SHUT WHEN NOT ON USE $259 $125 Implemented
LS1423 # 05 Y:2023 05 2023 INSTALL OCCUPANCY SENSORS $277 $200 Implemented
LS1323 # 01 Y:2023 01 2023 INSTALL OCCUPANCY SENSORS $969 $50 Implemented
LS1323 # 02 Y:2023 02 2023 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $1,720 $135 Implemented
LS1323 # 03 Y:2023 03 2023 INSTALL TIMERS AND/OR THERMOSTATS $890 $150 Implemented
LS1323 # 04 Y:2023 04 2023 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $535 $544 Implemented
LS1323 # 05 Y:2023 05 2023 USE SOLAR HEAT TO MAKE ELECTRICTY $11,358 $34,650 Not Implemented