Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
4,874
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
CO0212 # 03 Y:1991 | 03 | 1991 | INSTALL TIMERS AND/OR THERMOSTATS | $4,840 | $4,200 | Implemented |
CO0212 # 04 Y:1991 | 04 | 1991 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $3,061 | $10,000 | Implemented |
CO0212 # 05 Y:1991 | 05 | 1991 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $337 | $559 | Implemented |
CO0212 # 06 Y:1991 | 06 | 1991 | SCHEDULE USE OF ELEVATORS TO CONSERVE ENERGY | $920 | $300 | Implemented |
CO0213 # 01 Y:1991 | 01 | 1991 | RECOVER AND REUSE COOLING WATER | $52,663 | $0 | Not Implemented |
CO0213 # 02 Y:1991 | 02 | 1991 | INCREASE AMOUNT OF CONDENSATE RETURNED | $6,000 | $0 | Not Implemented |
CO0213 # 03 Y:1991 | 03 | 1991 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,900 | $900 | Not Implemented |
CO0213 # 04 Y:1991 | 04 | 1991 | INSTALL TIMERS AND/OR THERMOSTATS | $1,600 | $700 | Not Implemented |
CO0213 # 05 Y:1991 | 05 | 1991 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $1,274 | $2,548 | Not Implemented |
CO0213 # 06 Y:1991 | 06 | 1991 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $400 | $300 | Not Implemented |
CO0213 # 07 Y:1991 | 07 | 1991 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $4,700 | $1,500 | Not Implemented |
CO0213 # 08 Y:1991 | 08 | 1991 | UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED | $5,100 | $14,500 | Not Implemented |
CO0213 # 09 Y:1991 | 09 | 1991 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $5,300 | $18,000 | Not Implemented |
CO0213 # 10 Y:1991 | 10 | 1991 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $1,600 | $4,200 | Not Implemented |
CO0214 # 01 Y:1991 | 01 | 1991 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $4,100 | $5,700 | Not Implemented |
CO0214 # 02 Y:1991 | 02 | 1991 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $769 | $280 | Not Implemented |
CO0214 # 03 Y:1991 | 03 | 1991 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $479 | $200 | Not Implemented |
CO0214 # 04 Y:1991 | 04 | 1991 | UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED | $922 | $2,575 | Not Implemented |
CO0214 # 05 Y:1991 | 05 | 1991 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $8,050 | $25,000 | Not Implemented |
CO0214 # 06 Y:1991 | 06 | 1991 | USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE | $950 | $6,500 | Not Implemented |
CO0211 # 01 Y:1991 | 01 | 1991 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $3,840 | $250 | Implemented |
CO0211 # 02 Y:1991 | 02 | 1991 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,625 | $912 | Implemented |
CO0211 # 03 Y:1991 | 03 | 1991 | INSTALL SET-BACK TIMERS | $970 | $1,600 | Implemented |
CO0211 # 04 Y:1991 | 04 | 1991 | USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE | $460 | $100 | Implemented |
CO0211 # 05 Y:1991 | 05 | 1991 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $49 | $145 | Implemented |