IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

4,032

matching recommendations
Reset
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
KU0068 # 02 Y:1983 02 1983 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS $12,920 $6,931 Implemented
KU0068 # 03 Y:1983 03 1983 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $4,647 $20,000 Implemented
KU0068 # 04 Y:1983 04 1983 INSTALL TIMERS AND/OR THERMOSTATS $3,656 $149 Implemented
KU0068 # 05 Y:1983 05 1983 OPTIMIZE PLANT POWER FACTOR $3,507 $1,685 Implemented
KU0068 # 06 Y:1983 06 1983 CENTRALIZE CONTROL OF EXHAUST FANS TO ENSURE THEIR SHUTDOWN, OR ESTABLISH PROGRAM TO ENSURE MANUAL SHUTDOWN $1,291 $0 Not Implemented
KU0068 # 07 Y:1983 07 1983 REDUCE VENTILATION AIR $3,114 $0 Not Implemented
KU0068 # 08 Y:1983 08 1983 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $1,464 $0 Not Implemented
KU0068 # 09 Y:1983 09 1983 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $575 $358 Implemented
KU0069 # 01 Y:1983 01 1983 REPLACE BROKEN WINDOWS AND/OR WINDOW SASH $1,931 $500 Not Implemented
KU0069 # 02 Y:1983 02 1983 BURN WOOD BY-PRODUCTS FOR HEAT $1,077 $200 Not Implemented
KU0069 # 03 Y:1983 03 1983 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $535 $810 Implemented
KU0069 # 04 Y:1983 04 1983 INSTALL AUTOMATIC STACK DAMPER $352 $624 Not Implemented
KU0069 # 05 Y:1983 05 1983 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $324 $128 Implemented
KU0069 # 06 Y:1983 06 1983 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $251 $390 Implemented
KU0069 # 07 Y:1983 07 1983 USE ONLY AMOUNT OF AIR NECESSARY TO PREVENT EXPLOSION HAZARD $75 $50 Not Implemented
KU0072 # 01 Y:1983 01 1983 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $2,507 $2,164 Not Implemented
KU0072 # 02 Y:1983 02 1983 CLOSE HOLES AND OPENINGS IN BUILDING SUCH AS BROKEN WINDOWS $6,501 $1,660 Not Implemented
KU0072 # 03 Y:1983 03 1983 INSTALL TIMERS AND/OR THERMOSTATS $3,142 $100 Not Implemented
KU0072 # 04 Y:1983 04 1983 SHIFT FROM DAYTIME TO NIGHTTIME OPERATION $1,843 $0 Not Implemented
KU0072 # 05 Y:1983 05 1983 CLOSE HOLES AND OPENINGS IN BUILDING SUCH AS BROKEN WINDOWS $2,160 $837 Not Implemented
KU0072 # 06 Y:1983 06 1983 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $269 $200 Not Implemented
KU0072 # 07 Y:1983 07 1983 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $537 $200 Not Implemented
KU0072 # 08 Y:1983 08 1983 INSTALL AUTOMATIC STACK DAMPER $617 $700 Not Implemented
KU0072 # 09 Y:1983 09 1983 INSTALL AUTOMATIC STACK DAMPER $537 $528 Not Implemented
KU0066 # 01 Y:1982 01 1982 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $4,340 $3,302 Implemented