Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
4,767
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
TN0207 # 02 Y:1984 | 02 | 1984 | INSULATE BARE EQUIPMENT | $18,357 | $750 | Implemented |
TN0207 # 03 Y:1984 | 03 | 1984 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $8,215 | $21,000 | Implemented |
TN0207 # 04 Y:1984 | 04 | 1984 | INSTALL SET-BACK TIMERS | $645 | $0 | Implemented |
TN0207 # 05 Y:1984 | 05 | 1984 | INSULATE BARE EQUIPMENT | $250 | $78 | Not Implemented |
TN0208 # 01 Y:1984 | 01 | 1984 | AIR CONDITION ONLY SPACE NECESSARY | $2,708 | $132 | Not Implemented |
TN0208 # 02 Y:1984 | 02 | 1984 | INSTALL STORM WINDOWS AND DOORS | $731 | $123 | Not Implemented |
TN0201 # 01 Y:1984 | 01 | 1984 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $5,160 | $10 | Implemented |
TN0201 # 02 Y:1984 | 02 | 1984 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,336 | $2,325 | Implemented |
TN0201 # 03 Y:1984 | 03 | 1984 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $610 | $2,500 | Not Implemented |
TN0201 # 04 Y:1984 | 04 | 1984 | INSTALL / REPAIR INSULATION ON CONDENSATE LINES | $94 | $45 | Implemented |
TN0202 # 01 Y:1984 | 01 | 1984 | LOWER CEILING TO REDUCE CONDITIONED SPACE | $283 | $3,500 | Implemented |
TN0202 # 02 Y:1984 | 02 | 1984 | REDUCE VENTILATION AIR | $48 | $250 | Implemented |
TN0202 # 03 Y:1984 | 03 | 1984 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $87 | $20 | Implemented |
TN0202 # 04 Y:1984 | 04 | 1984 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $16 | $0 | Implemented |
TN0203 # 01 Y:1984 | 01 | 1984 | USE HOT PROCESS FLUIDS TO PREHEAT INCOMING PROCESS FLUIDS | $49,685 | $7,200 | Implemented |
TN0203 # 02 Y:1984 | 02 | 1984 | TURN OFF EQUIPMENT WHEN NOT IN USE | $21,920 | $0 | Not Implemented |
TN0203 # 03 Y:1984 | 03 | 1984 | ADJUST VENTS TO MINIMIZE ENERGY USE | $7,310 | $20,000 | Implemented |
TN0203 # 04 Y:1984 | 04 | 1984 | INSULATE BARE EQUIPMENT | $2,840 | $232 | Implemented |
TN0203 # 05 Y:1984 | 05 | 1984 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $1,679 | $0 | Implemented |
TN0203 # 06 Y:1984 | 06 | 1984 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $150 | $200 | Implemented |
TN0204 # 01 Y:1984 | 01 | 1984 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $8,740 | $600 | Not Implemented |
TN0204 # 02 Y:1984 | 02 | 1984 | USE MINIMUM STEAM OPERATING PRESSURE | $4,364 | $0 | Not Implemented |
TN0204 # 03 Y:1984 | 03 | 1984 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $5,302 | $0 | Not Implemented |
TN0204 # 04 Y:1984 | 04 | 1984 | COVER OPEN TANKS | $2,118 | $250 | Not Implemented |
TN0204 # 05 Y:1984 | 05 | 1984 | REPAIR AND ELIMINATE STEAM LEAKS | $1,573 | $140 | Implemented |