Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
4,767
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
TN0155 # 02 Y:1982 | 02 | 1982 | INSULATE BARE EQUIPMENT | $2,125 | $168 | Not Implemented |
TN0157 # 01 Y:1982 | 01 | 1982 | INSULATE BARE EQUIPMENT | $3,340 | $6,000 | Not Implemented |
TN0157 # 02 Y:1982 | 02 | 1982 | RE-USE OR RECYCLE HOT OR COLD PROCESS EXHAUST AIR | $576 | $1,400 | Not Implemented |
TN0157 # 03 Y:1982 | 03 | 1982 | USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE | $140 | $64 | Not Implemented |
TN0133 # 01 Y:1982 | 01 | 1982 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $7,497 | $100 | Not Implemented |
TN0133 # 02 Y:1982 | 02 | 1982 | INSTALL / REPAIR INSULATION ON STEAM LINES | $4,475 | $570 | Not Implemented |
TN0133 # 03 Y:1982 | 03 | 1982 | USE MINIMUM SAFE OVEN VENTILATION | $996 | $0 | Not Implemented |
TN0133 # 04 Y:1982 | 04 | 1982 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $308 | $0 | Not Implemented |
TN0135 # 01 Y:1982 | 01 | 1982 | INSTALL / REPAIR INSULATION ON STEAM LINES | $600 | $200 | Not Implemented |
TN0135 # 02 Y:1982 | 02 | 1982 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $2,400 | $300 | Not Implemented |
TN0137 # 01 Y:1982 | 01 | 1982 | REPLACE HYDRAULIC / PNEUMATIC EQUIPMENT WITH ELECTRIC EQUIPMENT | $1,517 | $1,635 | Not Implemented |
TN0137 # 02 Y:1982 | 02 | 1982 | INSTALL TIMERS AND/OR THERMOSTATS | $500 | $510 | Not Implemented |
TN0137 # 03 Y:1982 | 03 | 1982 | USE RADIANT HEATER FOR SPOT HEATING | $305 | $996 | Not Implemented |
TN0137 # 04 Y:1982 | 04 | 1982 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $131 | $0 | Not Implemented |
TN0139 # 01 Y:1982 | 01 | 1982 | INSTALL OR UPGRADE INSULATION ON HVAC DISTRIBUTION SYSTEMS | $6,842 | $0 | Not Implemented |
TN0139 # 02 Y:1982 | 02 | 1982 | KEEP LAMPS AND REFLECTORS CLEAN | $2,000 | $0 | Not Implemented |
TN0139 # 03 Y:1982 | 03 | 1982 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $4,800 | $0 | Not Implemented |
TN0140 # 01 Y:1982 | 01 | 1982 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $242 | $200 | Not Implemented |
TN0140 # 02 Y:1982 | 02 | 1982 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $66 | $48 | Not Implemented |
TN0140 # 03 Y:1982 | 03 | 1982 | MAINTAIN AIR FILTERS BY CLEANING OR REPLACEMENT | $185 | $0 | Not Implemented |
TN0142 # 01 Y:1982 | 01 | 1982 | USE SEPARATE SWITCHES ON PERIMETER LIGHTING WHICH MAY BE TURNED OFF WHEN NATURAL LIGHT IS AVAILABLE | $253 | $1,850 | Not Implemented |
TN0142 # 02 Y:1982 | 02 | 1982 | USE OPTIMUM THICKNESS INSULATION | $281 | $176 | Not Implemented |
TN0142 # 03 Y:1982 | 03 | 1982 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $472 | $500 | Not Implemented |
TN0144 # 01 Y:1982 | 01 | 1982 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,215 | $1,210 | Not Implemented |
TN0144 # 02 Y:1982 | 02 | 1982 | USE DEMAND CONTROLLER OR LOAD SHEDDER | $2,100 | $0 | Not Implemented |