Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
4,767
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
TN0149 # 01 Y:1982 | 01 | 1982 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $230 | $0 | Not Implemented |
TN0149 # 02 Y:1982 | 02 | 1982 | RECOVER WASTE HEAT FROM EQUIPMENT | $1,851 | $0 | Not Implemented |
TN0149 # 03 Y:1982 | 03 | 1982 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $5,508 | $45,000 | Not Implemented |
TN0129 # 01 Y:1982 | 01 | 1982 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $19,550 | $11,600 | Not Implemented |
TN0129 # 02 Y:1982 | 02 | 1982 | INSULATE BARE EQUIPMENT | $2,797 | $3,200 | Not Implemented |
TN0129 # 03 Y:1982 | 03 | 1982 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $2,972 | $5,000 | Not Implemented |
TN0129 # 04 Y:1982 | 04 | 1982 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $308 | $0 | Not Implemented |
TN0134 # 01 Y:1982 | 01 | 1982 | COVER OPEN TANKS | $12,000 | $3,500 | Not Implemented |
TN0134 # 02 Y:1982 | 02 | 1982 | INSULATE BARE EQUIPMENT | $700 | $4,000 | Not Implemented |
TN0134 # 03 Y:1982 | 03 | 1982 | OPTIMIZE PLANT POWER FACTOR | $10,000 | $12,000 | Not Implemented |
TN0138 # 01 Y:1982 | 01 | 1982 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $500 | $1,000 | Not Implemented |
TN0138 # 02 Y:1982 | 02 | 1982 | RECOVER WASTE HEAT FROM EQUIPMENT | $2,000 | $1,500 | Not Implemented |
TN0138 # 03 Y:1982 | 03 | 1982 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $370 | $800 | Not Implemented |
TN0122 # 01 Y:1982 | 01 | 1982 | USE OPTIMUM TEMPERATURE | $1,593 | $0 | Not Implemented |
TN0122 # 02 Y:1982 | 02 | 1982 | COVER OPEN TANKS | $467 | $900 | Not Implemented |
TN0122 # 03 Y:1982 | 03 | 1982 | LOWER LIGHT FIXTURES IN HIGH CEILING AREAS | $663 | $800 | Not Implemented |
TN0122 # 04 Y:1982 | 04 | 1982 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $481 | $82 | Not Implemented |
TN0124 # 01 Y:1982 | 01 | 1982 | USE RADIANT HEATER FOR SPOT HEATING | $1,715 | $8,360 | Not Implemented |
TN0124 # 02 Y:1982 | 02 | 1982 | CLOSE HOLES AND OPENINGS IN BUILDING SUCH AS BROKEN WINDOWS | $2,333 | $1,080 | Not Implemented |
TN0124 # 03 Y:1982 | 03 | 1982 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,101 | $11,060 | Not Implemented |
TN0124 # 04 Y:1982 | 04 | 1982 | INSTALL SET-BACK TIMERS | $2,998 | $60 | Not Implemented |
TN0128 # 01 Y:1982 | 01 | 1982 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,431 | $1,971 | Not Implemented |
TN0128 # 02 Y:1982 | 02 | 1982 | COVER OPEN TANKS | $2,342 | $400 | Not Implemented |
TN0128 # 03 Y:1982 | 03 | 1982 | RECOVER WASTE HEAT FROM EQUIPMENT | $2,660 | $4,250 | Not Implemented |
TN0130 # 01 Y:1982 | 01 | 1982 | TURN OFF EQUIPMENT WHEN NOT IN USE | $15,419 | $3,500 | Not Implemented |