IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

4,874

matching recommendations
Reset
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
CO0006 # 04 Y:1984 04 1984 USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE $820 $1,939 Implemented
CO0006 # 05 Y:1984 05 1984 RECOVER WASTE HEAT FROM EQUIPMENT $288 $150 Implemented
CO0006 # 06 Y:1984 06 1984 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS $2,708 $5,000 Not Implemented
CO0006 # 07 Y:1984 07 1984 INSTALL TIMERS AND/OR THERMOSTATS $347 $125 Implemented
CO0006 # 08 Y:1984 08 1984 REDUCE LOAD ON ELECTRICAL CONDUCTOR TO REDUCE HEATING LOSSES $134 $200 Implemented
CO0006 # 09 Y:1984 09 1984 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $164 $60 Implemented
CO0007 # 01 Y:1984 01 1984 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $4,798 $2,178 Implemented
CO0007 # 02 Y:1984 02 1984 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $166 $300 Implemented
CO0007 # 03 Y:1984 03 1984 RECOVER WASTE HEAT FROM EQUIPMENT $428 $100 Implemented
CO0007 # 04 Y:1984 04 1984 CLOSE HOLES AND OPENINGS IN BUILDING SUCH AS BROKEN WINDOWS $528 $21 Implemented
CO0007 # 05 Y:1984 05 1984 USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE $145 $221 Implemented
CO0007 # 06 Y:1984 06 1984 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $288 $275 Implemented
CO0007 # 07 Y:1984 07 1984 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS $4,282 $0 Implemented
CO0007 # 08 Y:1984 08 1984 INSTALL TIMERS AND/OR THERMOSTATS $2,099 $721 Implemented
CO0007 # 09 Y:1984 09 1984 SEPARATE CONTROLS OF AIR HANDLERS FROM AC/ HEATING SYSTEMS $370 $400 Implemented
CO0007 # 10 Y:1984 10 1984 USE FLOW CONTROL VALVES ON EQUIPMENT TO OPTIMIZE WATER USE $1,029 $25 Implemented
CO0002 # 01 Y:1984 01 1984 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $35,148 $10,260 Implemented
CO0002 # 02 Y:1984 02 1984 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $8,158 $300 Not Implemented
CO0002 # 03 Y:1984 03 1984 INSTALL STEAM TRAP $1,507 $254 Implemented
CO0002 # 04 Y:1984 04 1984 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT $814 $250 Not Implemented
CO0002 # 05 Y:1984 05 1984 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $1,061 $0 Implemented
CO0002 # 06 Y:1984 06 1984 OPTIMIZE PLANT POWER FACTOR $9,850 $10,000 Not Implemented
CO0002 # 07 Y:1984 07 1984 INSTALL TIMERS AND/OR THERMOSTATS $10,932 $1,557 Implemented
CO0003 # 01 Y:1984 01 1984 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $5,060 $300 Implemented
CO0003 # 02 Y:1984 02 1984 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $1,272 $2,500 Implemented