Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
5,754
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
OK0076 # 04 Y:1983 | 04 | 1983 | USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE | $172 | $386 | Implemented |
OK0078 # 01 Y:1983 | 01 | 1983 | INSTALL SET-BACK TIMERS | $1,033 | $0 | Not Implemented |
OK0078 # 02 Y:1983 | 02 | 1983 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,482 | $1,779 | Not Implemented |
OK0078 # 03 Y:1983 | 03 | 1983 | INSTALL TIMERS AND/OR THERMOSTATS | $13,322 | $100 | Not Implemented |
OK0078 # 04 Y:1983 | 04 | 1983 | USE DEMAND CONTROLLER OR LOAD SHEDDER | $2,697 | $0 | Not Implemented |
OK0081 # 01 Y:1983 | 01 | 1983 | USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE | $681 | $2,600 | Not Implemented |
OK0081 # 02 Y:1983 | 02 | 1983 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $1,518 | $1,800 | Implemented |
OK0081 # 03 Y:1983 | 03 | 1983 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $476 | $129 | Not Implemented |
OK0081 # 04 Y:1983 | 04 | 1983 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,437 | $188 | Not Implemented |
OK0084 # 01 Y:1983 | 01 | 1983 | USE DEMAND CONTROLLER OR LOAD SHEDDER | $4,150 | $913 | Not Implemented |
OK0084 # 02 Y:1983 | 02 | 1983 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $115 | $187 | Implemented |
OK0084 # 03 Y:1983 | 03 | 1983 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $248 | $203 | Not Implemented |
OK0084 # 04 Y:1983 | 04 | 1983 | INSTALL TIMERS AND/OR THERMOSTATS | $178 | $377 | Not Implemented |
OK0084 # 05 Y:1983 | 05 | 1983 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $800 | $180 | Not Implemented |
OK0084 # 06 Y:1983 | 06 | 1983 | USE OPTIMUM THICKNESS INSULATION | $1,025 | $832 | Not Implemented |
OK0084 # 07 Y:1983 | 07 | 1983 | USE HIGHEST TEMPERATURE FOR CHILLING OR COLD STORAGE | $4,195 | $300 | Not Implemented |
OK0084 # 08 Y:1983 | 08 | 1983 | MINIMIZE OPERATION OF EQUIPMENT MAINTAINED IN STANDBY CONDITION | $332 | $45 | Not Implemented |
OK0085 # 01 Y:1983 | 01 | 1983 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $331 | $198 | Not Implemented |
OK0085 # 02 Y:1983 | 02 | 1983 | INSTALL TIMERS AND/OR THERMOSTATS | $661 | $642 | Implemented |
OK0085 # 03 Y:1983 | 03 | 1983 | USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE | $437 | $1,445 | Implemented |
OK0085 # 04 Y:1983 | 04 | 1983 | USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE | $422 | $1,500 | Implemented |
OK0088 # 01 Y:1983 | 01 | 1983 | REPLACE PURCHASED STEAM WITH OTHER ENERGY SOURCE | $2,343 | $5,600 | Not Implemented |
OK0088 # 02 Y:1983 | 02 | 1983 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $147 | $292 | Not Implemented |
OK0088 # 03 Y:1983 | 03 | 1983 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $82 | $70 | Not Implemented |
OK0088 # 04 Y:1983 | 04 | 1983 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $960 | $2,170 | Not Implemented |