Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
8,682
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
ND0158 # 03 Y:1993 | 03 | 1993 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $250 | $240 | n/a |
ND0158 # 04 Y:1993 | 04 | 1993 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,058 | $849 | n/a |
ND0158 # 05 Y:1993 | 05 | 1993 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,142 | $1,525 | n/a |
ND0158 # 06 Y:1993 | 06 | 1993 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $260 | $459 | n/a |
ND0158 # 07 Y:1993 | 07 | 1993 | PAY UTILITY BILLS ON TIME | $25,013 | $0 | n/a |
WI0180 # 01 Y:1993 | 01 | 1993 | MINIMIZE USE OF OUTSIDE MAKE-UP AIR FOR VENTILATION EXCEPT WHEN USED FOR ECONOMIZER CYCLE | $17,501 | $0 | Implemented |
WI0180 # 02 Y:1993 | 02 | 1993 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $12,585 | $17,728 | Not Implemented |
WI0180 # 03 Y:1993 | 03 | 1993 | INSTALL OCCUPANCY SENSORS | $9,793 | $3,450 | Implemented |
WI0180 # 04 Y:1993 | 04 | 1993 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,508 | $6,708 | Implemented |
WI0180 # 05 Y:1993 | 05 | 1993 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $7,804 | $18,262 | Implemented |
WI0180 # 06 Y:1993 | 06 | 1993 | INSULATE BARE EQUIPMENT | $2,007 | $51 | Implemented |
WI0180 # 07 Y:1993 | 07 | 1993 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $4,220 | $0 | Not Implemented |
WI0180 # 08 Y:1993 | 08 | 1993 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $2,009 | $1,067 | Not Implemented |
WI0180 # 09 Y:1993 | 09 | 1993 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $3,744 | $2,800 | Not Implemented |
WI0180 # 10 Y:1993 | 10 | 1993 | RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS | $3,494 | $0 | Implemented |
WI0180 # 11 Y:1993 | 11 | 1993 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $3,167 | $10,000 | Not Implemented |
WI0180 # 12 Y:1993 | 12 | 1993 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $498 | $500 | Implemented |
WI0180 # 13 Y:1993 | 13 | 1993 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $1,451 | $3,410 | Not Implemented |
WI0180 # 14 Y:1993 | 14 | 1993 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $841 | $900 | Not Implemented |
WI0180 # 15 Y:1993 | 15 | 1993 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $730 | $700 | Not Implemented |
WI0179 # 01 Y:1993 | 01 | 1993 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $2,974 | $4,960 | Not Implemented |
WI0179 # 02 Y:1993 | 02 | 1993 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,295 | $5,659 | Not Implemented |
WI0179 # 03 Y:1993 | 03 | 1993 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $1,270 | $0 | Implemented |
WI0179 # 04 Y:1993 | 04 | 1993 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $1,354 | $2,800 | Not Implemented |
WI0179 # 05 Y:1993 | 05 | 1993 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $776 | $500 | Not Implemented |