Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
5,474
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
ND0194 # 03 Y:1994 | 03 | 1994 | OPTIMIZE PLANT POWER FACTOR | $21,631 | $30,688 | Implemented |
ND0194 # 04 Y:1994 | 04 | 1994 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $18,480 | $900 | Not Implemented |
ND0194 # 05 Y:1994 | 05 | 1994 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $5,525 | $1,050 | Not Implemented |
ND0194 # 06 Y:1994 | 06 | 1994 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,162 | $7,693 | Implemented |
ND0194 # 07 Y:1994 | 07 | 1994 | INSTALL OCCUPANCY SENSORS | $3,796 | $400 | Not Implemented |
ND0194 # 08 Y:1994 | 08 | 1994 | REPAIR OR REPLACE STEAM TRAPS | $2,707 | $2,500 | Implemented |
ND0194 # 09 Y:1994 | 09 | 1994 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $1,576 | $200 | Implemented |
ND0194 # 10 Y:1994 | 10 | 1994 | DIRECT WARMEST AIR TO COMBUSTION INTAKE | $403 | $500 | Not Implemented |
ND0194 # 11 Y:1994 | 11 | 1994 | RE-SIZE CHARGING OPENINGS OR ADD MOVABLE COVER OR DOOR | $346 | $150 | Implemented |
ND0203 # 01 Y:1994 | 01 | 1994 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $13,693 | $750 | Not Implemented |
ND0203 # 02 Y:1994 | 02 | 1994 | REPLACE CITY WATER WITH RECYCLED WATER VIA COOLING TOWER | $13,400 | $13,000 | Not Implemented |
ND0203 # 03 Y:1994 | 03 | 1994 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $6,176 | $5,530 | Implemented |
ND0203 # 04 Y:1994 | 04 | 1994 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $5,325 | $5,045 | Implemented |
ND0203 # 05 Y:1994 | 05 | 1994 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $2,350 | $200 | Implemented |
ND0203 # 06 Y:1994 | 06 | 1994 | INSTALL OCCUPANCY SENSORS | $1,476 | $400 | Not Implemented |
ND0203 # 07 Y:1994 | 07 | 1994 | INSULATE GLAZING, WALLS, CEILINGS, AND ROOFS | $890 | $500 | Not Implemented |
ND0203 # 08 Y:1994 | 08 | 1994 | DIRECT WARMEST AIR TO COMBUSTION INTAKE | $600 | $500 | Not Implemented |
ND0203 # 09 Y:1994 | 09 | 1994 | CHECK FOR ACCURACY OF UTILITY / POWER METERS | $194 | $0 | Implemented |
ND0203 # 10 Y:1994 | 10 | 1994 | RE-SIZE CHARGING OPENINGS OR ADD MOVABLE COVER OR DOOR | $87 | $40 | Implemented |
OD0010 # 01 Y:1994 | 01 | 1994 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,348 | $3,873 | Implemented |
OD0010 # 02 Y:1994 | 02 | 1994 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $965 | $800 | Implemented |
OD0010 # 03 Y:1994 | 03 | 1994 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,624 | $25 | Implemented |
OD0010 # 04 Y:1994 | 04 | 1994 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $927 | $7,684 | Implemented |
OD0010 # 05 Y:1994 | 05 | 1994 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $323 | $187 | Implemented |
OK0452 # 01 Y:1994 | 01 | 1994 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $17,658 | $12,000 | Implemented |