Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
9,980
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UD0312 # 02 Y:1990 | 02 | 1990 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,262 | $7,825 | Implemented |
UD0312 # 03 Y:1990 | 03 | 1990 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,422 | $2,000 | Implemented |
UD0312 # 04 Y:1990 | 04 | 1990 | OPTIMIZE PLANT POWER FACTOR | $157,000 | $220,000 | Not Implemented |
UD0312 # 05 Y:1990 | 05 | 1990 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $18,569 | $0 | Not Implemented |
UD0312 # 06 Y:1990 | 06 | 1990 | PREHEAT BOILER MAKEUP WATER WITH WASTE PROCESS HEAT | $8,884 | $0 | Implemented |
UD0312 # 07 Y:1990 | 07 | 1990 | USE MOST EFFICIENT EQUIPMENT AT IT'S MAXIMUM CAPACITY AND LESS EFFICIENT EQUIPMENT ONLY WHEN NECESSARY | $6,775 | $5,000 | Not Implemented |
UD0312 # 08 Y:1990 | 08 | 1990 | INSTALL TIMERS AND/OR THERMOSTATS | $21,868 | $12,000 | Not Implemented |
UD0312 # 09 Y:1990 | 09 | 1990 | REPAIR AND ELIMINATE STEAM LEAKS | $24,995 | $0 | Implemented |
UD0312 # 10 Y:1990 | 10 | 1990 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $58,168 | $100,000 | Not Implemented |
UD0309 # 01 Y:1990 | 01 | 1990 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $13,076 | $18,000 | Not Implemented |
UD0309 # 02 Y:1990 | 02 | 1990 | INSTALL TIMERS AND/OR THERMOSTATS | $3,951 | $700 | Implemented |
UD0309 # 03 Y:1990 | 03 | 1990 | AIR CONDITION ONLY SPACE NECESSARY | $1,295 | $200 | Implemented |
UD0309 # 04 Y:1990 | 04 | 1990 | RECOVER WASTE HEAT FROM EQUIPMENT | $3,374 | $8,000 | Not Implemented |
UD0309 # 05 Y:1990 | 05 | 1990 | INSTALL SET-BACK TIMERS | $900 | $500 | Not Implemented |
UD0309 # 06 Y:1990 | 06 | 1990 | USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING | $8,028 | $10,000 | Implemented |
UD0310 # 01 Y:1990 | 01 | 1990 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $1,258 | $0 | Not Implemented |
UD0310 # 02 Y:1990 | 02 | 1990 | SHUT OFF PILOTS IN STANDBY EQUIPMENT | $862 | $0 | Implemented |
UD0310 # 03 Y:1990 | 03 | 1990 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $170 | $0 | Implemented |
UD0310 # 04 Y:1990 | 04 | 1990 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,326 | $442 | Implemented |
UD0310 # 05 Y:1990 | 05 | 1990 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $907 | $1,800 | Implemented |
UD0310 # 06 Y:1990 | 06 | 1990 | USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE | $4,867 | $25,000 | Not Implemented |
UD0307 # 01 Y:1990 | 01 | 1990 | USE FLOW CONTROL VALVES ON EQUIPMENT TO OPTIMIZE WATER USE | $4,728 | $100 | Implemented |
UD0307 # 02 Y:1990 | 02 | 1990 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $140 | $200 | Not Implemented |
UD0307 # 03 Y:1990 | 03 | 1990 | USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE | $721 | $1,425 | Not Implemented |
UD0302 # 01 Y:1990 | 01 | 1990 | USE MOST EFFICIENT EQUIPMENT AT IT'S MAXIMUM CAPACITY AND LESS EFFICIENT EQUIPMENT ONLY WHEN NECESSARY | $2,135 | $0 | Implemented |