Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

5,474

matching recommendations
Reset
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
MS0004 # 02 Y:1994 02 1994 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $10,637 $20,000 Not Implemented
MS0004 # 03 Y:1994 03 1994 MAINTAIN AIR FILTERS BY CLEANING OR REPLACEMENT $2,702 $651 Not Implemented
MS0004 # 04 Y:1994 04 1994 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $4,560 $12,000 Not Implemented
MS0004 # 05 Y:1994 05 1994 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $1,458 $2,600 Not Implemented
MS0008 # 01 Y:1994 01 1994 SIZE ELECTRIC MOTORS FOR PEAK OPERATING EFFICIENCY $5,885 $1,000 Not Implemented
MS0008 # 02 Y:1994 02 1994 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT $6,252 $10,100 Not Implemented
MS0008 # 03 Y:1994 03 1994 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,373 $502 Not Implemented
MS0008 # 04 Y:1994 04 1994 RECOVER WASTE HEAT FROM EQUIPMENT $428 $1,000 Not Implemented
MS0008 # 05 Y:1994 05 1994 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $164 $116 Not Implemented
MS0008 # 06 Y:1994 06 1994 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $222 $700 Not Implemented
UF0095 # 01 Y:1994 01 1994 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $32,948 $39,507 Implemented
UF0095 # 02 Y:1994 02 1994 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $1,388 $1,750 Implemented
UF0095 # 03 Y:1994 03 1994 REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL $16,867 $24,660 Implemented
UF0095 # 04 Y:1994 04 1994 MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE $6,763 $22,550 Not Implemented
UF0095 # 05 Y:1994 05 1994 REPLACE ELECTRIC REHEAT WITH HEAT PIPES $11,259 $38,450 Not Implemented
UF0095 # 06 Y:1994 06 1994 MAKE ICE DURING OFF PEAK HOURS FOR COOLING $49,423 $76,330 Not Implemented
UF0095 # 07 Y:1994 07 1994 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $554 $794 Implemented
AM0220 # 01 Y:1994 01 1994 OPTIMIZE PLANT POWER FACTOR $96,105 $145,000 Implemented
AM0220 # 02 Y:1994 02 1994 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT $44,845 $120,000 Implemented
AM0220 # 03 Y:1994 03 1994 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT $37,861 $92,046 Implemented
AM0220 # 04 Y:1994 04 1994 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $26,620 $3,800 Implemented
AM0220 # 05 Y:1994 05 1994 INSTALL OCCUPANCY SENSORS $12,915 $6,250 Implemented
AM0220 # 06 Y:1994 06 1994 WASH AND REUSE RAGS ON-SITE $2,070 $7,900 Implemented
AM0220 # 07 Y:1994 07 1994 USE LESS TOXIC AND VOLATILE SOLVENT SUBSTITUTES $670 $2,400 Implemented
KU0443 # 01 Y:1994 01 1994 RECOVER WASTE HEAT FROM EQUIPMENT $76,353 $131,600 Not Implemented