Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
2,629
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
KU0251 # 02 Y:1988 | 02 | 1988 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $354 | $400 | Not Implemented |
KU0251 # 03 Y:1988 | 03 | 1988 | IMPROVE LUBRICATION PRACTICES | $530 | $0 | Implemented |
KU0251 # 04 Y:1988 | 04 | 1988 | INSTALL AUTOMATIC STACK DAMPER | $297 | $150 | Not Implemented |
KU0251 # 05 Y:1988 | 05 | 1988 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $287 | $0 | Not Implemented |
KU0251 # 06 Y:1988 | 06 | 1988 | KEEP DOORS AND WINDOWS SHUT WHEN NOT ON USE | $209 | $0 | Implemented |
KU0251 # 07 Y:1988 | 07 | 1988 | APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES | $173 | $0 | Implemented |
KU0251 # 08 Y:1988 | 08 | 1988 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $187 | $0 | Implemented |
KU0251 # 09 Y:1988 | 09 | 1988 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $133 | $0 | Implemented |
KU0252 # 01 Y:1988 | 01 | 1988 | USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE | $4,182 | $7,500 | Implemented |
KU0252 # 02 Y:1988 | 02 | 1988 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,238 | $200 | Implemented |
KU0252 # 03 Y:1988 | 03 | 1988 | USE PROPERLY DESIGNED AND SIZED HVAC EQUIPMENT | $2,500 | $3,600 | Not Implemented |
KU0252 # 04 Y:1988 | 04 | 1988 | USE PROPERLY DESIGNED AND SIZED HVAC EQUIPMENT | $2,095 | $1,200 | Not Implemented |
KU0252 # 05 Y:1988 | 05 | 1988 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $1,381 | $0 | Implemented |
KU0249 # 01 Y:1988 | 01 | 1988 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $12,925 | $3,000 | Implemented |
KU0249 # 02 Y:1988 | 02 | 1988 | APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES | $16,086 | $0 | Not Implemented |
KU0249 # 03 Y:1988 | 03 | 1988 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $8,841 | $0 | Implemented |
KU0249 # 04 Y:1988 | 04 | 1988 | INSTALL TURBULATORS | $4,220 | $1,600 | Not Implemented |
KU0249 # 05 Y:1988 | 05 | 1988 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $2,965 | $5,000 | Not Implemented |
KU0249 # 06 Y:1988 | 06 | 1988 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,117 | $3,191 | Not Implemented |
KU0249 # 07 Y:1988 | 07 | 1988 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,709 | $800 | Not Implemented |
KU0249 # 08 Y:1988 | 08 | 1988 | IMPROVE LUBRICATION PRACTICES | $1,098 | $0 | Implemented |
KU0250 # 01 Y:1988 | 01 | 1988 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $7,460 | $9,000 | Implemented |
KU0250 # 02 Y:1988 | 02 | 1988 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $5,440 | $10,000 | Implemented |
KU0250 # 03 Y:1988 | 03 | 1988 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $520 | $60 | Not Implemented |
KU0250 # 04 Y:1988 | 04 | 1988 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,679 | $2,000 | Implemented |