Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
2,616
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UA0053 # 02 Y:2010 | 02 | 2010 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,266 | $13,725 | Not Implemented |
UA0053 # 03 Y:2010 | 03 | 2010 | INSTALL OCCUPANCY SENSORS | $2,400 | $1,080 | Not Implemented |
UA0053 # 04 Y:2010 | 04 | 2010 | USE PHOTOCELL CONTROLS | $218 | $177 | Implemented |
UA0053 # 05 Y:2010 | 05 | 2010 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $351 | $906 | Implemented |
UA0053 # 06 Y:2010 | 06 | 2010 | KEEP DOORS AND WINDOWS SHUT WHEN NOT ON USE | $4,505 | $1,000 | Implemented |
UA0053 # 07 Y:2010 | 07 | 2010 | RECOVER WASTE HEAT FROM EQUIPMENT | $12,870 | $26,550 | Not Implemented |
UA0053 # 08 Y:2010 | 08 | 2010 | USE OPTIMUM SIZE AND CAPACITY EQUIPMENT | $3,306 | $7,045 | Not Implemented |
UA0053 # 09 Y:2010 | 09 | 2010 | USE A LESS EXPENSIVE METHOD OF WASTE REMOVAL | $27,920 | $8,875 | Not Implemented |
UA0052 # 01 Y:2010 | 01 | 2010 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $9,025 | $10,875 | Implemented |
UA0052 # 02 Y:2010 | 02 | 2010 | INSTALL OCCUPANCY SENSORS | $852 | $470 | Not Implemented |
UA0052 # 03 Y:2010 | 03 | 2010 | INSTALL OCCUPANCY SENSORS | $168 | $97 | Not Implemented |
UA0052 # 04 Y:2010 | 04 | 2010 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $6,369 | $640 | Not Implemented |
UA0052 # 05 Y:2010 | 05 | 2010 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $10,183 | $1,500 | Implemented |
UA0052 # 06 Y:2010 | 06 | 2010 | USE RADIANT HEATER FOR SPOT HEATING | $2,198 | $5,028 | Not Implemented |
UA0052 # 07 Y:2010 | 07 | 2010 | INSTALL TIMERS AND/OR THERMOSTATS | $3,116 | $850 | Not Implemented |
UA0052 # 08 Y:2010 | 08 | 2010 | REPLACE EXISTING EQUIPMENT WITH MORE SUITABLE SUBSTITUTES | $11,400 | $10,000 | Not Implemented |
UA0051 # 01 Y:2010 | 01 | 2010 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $9,487 | $1,000 | Not Implemented |
UA0051 # 02 Y:2010 | 02 | 2010 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $29,840 | $10,000 | Implemented |
UA0051 # 03 Y:2010 | 03 | 2010 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,427 | $4,500 | Implemented |
UA0051 # 04 Y:2010 | 04 | 2010 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $7,331 | $640 | Not Implemented |
UA0051 # 05 Y:2010 | 05 | 2010 | USE OPTIMUM SIZE AND CAPACITY EQUIPMENT | $8,177 | $5,219 | Implemented |
UA0051 # 06 Y:2010 | 06 | 2010 | PROVIDE PROPER MAINTENANCE OF MOTOR DRIVEN EQUIPMENT | $48,136 | $21,075 | Not Implemented |
UA0050 # 01 Y:2010 | 01 | 2010 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $75,096 | $640 | Not Implemented |
UA0050 # 02 Y:2010 | 02 | 2010 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $123,482 | $302,000 | Implemented |
UA0050 # 03 Y:2010 | 03 | 2010 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $42,529 | $45,740 | Implemented |