Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
1,152
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UD0061 # 02 Y:1982 | 02 | 1982 | REDUCE HOT WATER TEMPERATURE TO THE MINIMUM REQUIRED | $72 | $0 | Implemented |
UD0061 # 03 Y:1982 | 03 | 1982 | RECOVER WASTE HEAT FROM EQUIPMENT | $820 | $270 | Not Implemented |
UD0061 # 04 Y:1982 | 04 | 1982 | USE PROPERLY DESIGNED AND SIZED HVAC EQUIPMENT | $177 | $500 | Not Implemented |
UD0062 # 01 Y:1982 | 01 | 1982 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $10,658 | $1,240 | Not Implemented |
UD0062 # 02 Y:1982 | 02 | 1982 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $4,859 | $25,000 | Not Implemented |
UD0063 # 01 Y:1982 | 01 | 1982 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $17,852 | $63,993 | Not Implemented |
UD0063 # 02 Y:1982 | 02 | 1982 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $17,588 | $2,222 | Not Implemented |
UD0063 # 03 Y:1982 | 03 | 1982 | RECOVER WASTE HEAT FROM EQUIPMENT | $1,592 | $61 | Implemented |
UD0063 # 04 Y:1982 | 04 | 1982 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $29,194 | $42,215 | Implemented |
UD0064 # 01 Y:1982 | 01 | 1982 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $12,885 | $11,043 | Implemented |
UD0064 # 02 Y:1982 | 02 | 1982 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $14,605 | $8,000 | Not Implemented |
UD0064 # 03 Y:1982 | 03 | 1982 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,486 | $2,126 | Implemented |
UD0064 # 04 Y:1982 | 04 | 1982 | USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE | $2,281 | $2,200 | Implemented |
UD0064 # 05 Y:1982 | 05 | 1982 | REDUCE HOT WATER TEMPERATURE TO THE MINIMUM REQUIRED | $240 | $120 | Not Implemented |
UD0067 # 01 Y:1982 | 01 | 1982 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,431 | $250 | Implemented |
UD0067 # 02 Y:1982 | 02 | 1982 | USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE | $12,896 | $64,600 | Implemented |
UD0067 # 03 Y:1982 | 03 | 1982 | INSTALL STORM WINDOWS AND DOORS | $6,999 | $7,642 | Implemented |
UD0067 # 04 Y:1982 | 04 | 1982 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $1,770 | $0 | Implemented |
UD0067 # 05 Y:1982 | 05 | 1982 | UTILIZE OUTSIDE AIR INSTEAD OF CONDITIONED AIR FOR DRYING | $1,207 | $286 | Implemented |
OK0058 # 01 Y:1982 | 01 | 1982 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $261 | $270 | Implemented |
OK0058 # 02 Y:1982 | 02 | 1982 | REPLACE GASOLINE WITH DIESEL, LPG, OR NATURAL GAS | $19,472 | $16,000 | Not Implemented |
OK0058 # 03 Y:1982 | 03 | 1982 | PLANT TREES OR SHRUBS NEAR WINDOWS TO SHIELD FROM SUNLIGHT | $194 | $475 | Implemented |
OK0058 # 04 Y:1982 | 04 | 1982 | USE UTILITY CONTROLLED POWER MANAGEMENT | $365 | $0 | Implemented |
OK0063 # 01 Y:1982 | 01 | 1982 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,442 | $400 | Not Implemented |
OK0063 # 02 Y:1982 | 02 | 1982 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $345 | $156 | Not Implemented |