Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
7,713
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UF0505 # 01 Y:2017 | 01 | 2017 | USE A FOSSIL FUEL ENGINE TO COGENERATE ELECTRICITY OR MOTIVE POWER; AND UTILIZE HEAT | $715,231 | $1,700,000 | Not Implemented |
UF0505 # 02 Y:2017 | 02 | 2017 | REPLACE BOILER | $152,736 | $200,000 | Implemented |
UF0505 # 03 Y:2017 | 03 | 2017 | INCREASE AMOUNT OF CONDENSATE RETURNED | $18,902 | $2,800 | Implemented |
UF0505 # 04 Y:2017 | 04 | 2017 | ESTABLISH A PREVENTATIVE MAINTENANCE PROGRAM | $13,763 | $120 | Implemented |
UF0505 # 05 Y:2017 | 05 | 2017 | INSTALL TURBULATORS | $12,705 | $7,500 | Not Implemented |
UF0505 # 06 Y:2017 | 06 | 2017 | REPAIR AND ELIMINATE STEAM LEAKS | $7,831 | $1,081 | Implemented |
UF0505 # 07 Y:2017 | 07 | 2017 | PREHEAT BOILER MAKEUP WATER WITH WASTE PROCESS HEAT | $7,374 | $4,000 | Not Implemented |
UF0505 # 08 Y:2017 | 08 | 2017 | REPAIR AND ELIMINATE STEAM LEAKS | $4,554 | $1,592 | Implemented |
UF0504 # 01 Y:2017 | 01 | 2017 | USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE | $12,636 | $39,000 | Not Implemented |
UF0504 # 02 Y:2017 | 02 | 2017 | ADD AREA LIGHTING SWITCHES | $2,381 | $2,240 | Not Implemented |
UF0504 # 03 Y:2017 | 03 | 2017 | MINIMIZE CONDENSER COOLING WATER TEMPERATURE | $1,236 | $700 | Not Implemented |
UF0504 # 04 Y:2017 | 04 | 2017 | DEVELOP STANDARD PROCEDURES TO IMPROVE INTERNAL YIELDS | $352,554 | $180,000 | Not Implemented |
UF0504 # 05 Y:2017 | 05 | 2017 | INSTALL AN UNINTERUPTABLE POWER SUPPLY | $15,187 | $28,820 | Not Implemented |
UF0504 # 06 Y:2017 | 06 | 2017 | RE-ARRANGE EQUIPMENT LAYOUT TO REDUCE HANDLING COSTS | $9,360 | $3,600 | Not Implemented |
UF0503 # 01 Y:2017 | 01 | 2017 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $69,770 | $7,000 | Not Implemented |
UF0503 # 02 Y:2017 | 02 | 2017 | UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED | $12,043 | $1,400 | Not Implemented |
UF0503 # 03 Y:2017 | 03 | 2017 | IMPROVE COMBUSTION CONTROL CAPABILITY | $9,797 | $2,182 | Not Implemented |
UF0503 # 04 Y:2017 | 04 | 2017 | REDUCE COMBUSTION AIR FLOW TO OPTIMUM | $4,014 | $0 | Not Implemented |
UF0503 # 05 Y:2017 | 05 | 2017 | TURN OFF EQUIPMENT WHEN NOT IN USE | $3,268 | $0 | Not Implemented |
UF0503 # 06 Y:2017 | 06 | 2017 | USE CONTINUOUS EQUIPMENT WHICH RETAINS PROCESS HEATING CONVEYORS WITHIN THE HEATED CHAMBER | $1,188 | $0 | Not Implemented |
UF0502 # 01 Y:2017 | 01 | 2017 | ADJUST BURNERS FOR EFFICIENT OPERATION | $292,994 | $0 | Not Implemented |
UF0502 # 02 Y:2017 | 02 | 2017 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $9,062 | $2,182 | Not Implemented |
UF0502 # 03 Y:2017 | 03 | 2017 | SIZE ELECTRIC MOTORS FOR PEAK OPERATING EFFICIENCY | $7,986 | $0 | Not Implemented |
UF0502 # 04 Y:2017 | 04 | 2017 | IMPROVE COMBUSTION CONTROL CAPABILITY | $2,634 | $0 | Not Implemented |
UF0502 # 05 Y:2017 | 05 | 2017 | REDESIGN PROCESS | $1,490 | $1,800 | Not Implemented |