Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
5,520
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
KU0536 # 06 Y:1999 | 06 | 1999 | IMPROVE SPACE COMFORT CONDITIONING | $34,860 | $75,000 | n/a |
MA0454 # 01 Y:1999 | 01 | 1999 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $11,113 | $11,700 | Not Implemented |
MA0454 # 02 Y:1999 | 02 | 1999 | OPTIMIZE PLANT POWER FACTOR | $5,776 | $16,250 | Not Implemented |
MA0454 # 03 Y:1999 | 03 | 1999 | METER RECYCLED WATER (TO REDUCE SEWER CHARGES) | $667 | $2,675 | Not Implemented |
MA0453 # 01 Y:1999 | 01 | 1999 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $60,085 | $139,425 | Not Implemented |
MA0453 # 02 Y:1999 | 02 | 1999 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $38,897 | $96,900 | Not Implemented |
MA0453 # 03 Y:1999 | 03 | 1999 | RECOVER WASTE HEAT FROM EQUIPMENT | $19,476 | $45,000 | Not Implemented |
MA0453 # 04 Y:1999 | 04 | 1999 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $10,766 | $19,425 | Not Implemented |
MA0453 # 05 Y:1999 | 05 | 1999 | USE LESS WASTEFUL PACKAGING | $8,714 | $15,000 | Not Implemented |
MA0453 # 06 Y:1999 | 06 | 1999 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $5,433 | $10,115 | Not Implemented |
NV0144 # 01 Y:1999 | 01 | 1999 | USE OPTIMUM THICKNESS INSULATION | $418 | $788 | Not Implemented |
NV0144 # 02 Y:1999 | 02 | 1999 | OPTIMIZE PLANT POWER FACTOR | $6,393 | $5,533 | Not Implemented |
NV0144 # 03 Y:1999 | 03 | 1999 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $6,668 | $800 | Implemented |
MS0149 # 01 Y:1999 | 01 | 1999 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $790 | $263 | Implemented |
MS0149 # 02 Y:1999 | 02 | 1999 | INSTALL TIMERS AND/OR THERMOSTATS | $74 | $119 | Not Implemented |
MS0149 # 03 Y:1999 | 03 | 1999 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $1,504 | $2,060 | Implemented |
MS0149 # 04 Y:1999 | 04 | 1999 | USE OPTIMUM THICKNESS INSULATION | $15,653 | $9,593 | Not Implemented |
MS0148 # 01 Y:1999 | 01 | 1999 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $8,990 | $30,779 | Not Implemented |
MS0148 # 02 Y:1999 | 02 | 1999 | USE SEPARATE SWITCHES ON PERIMETER LIGHTING WHICH MAY BE TURNED OFF WHEN NATURAL LIGHT IS AVAILABLE | $1,778 | $792 | Not Implemented |
MS0148 # 03 Y:1999 | 03 | 1999 | USE PHOTOCELL CONTROLS | $2,140 | $1,195 | Not Implemented |
MS0148 # 04 Y:1999 | 04 | 1999 | INSTALL TIMERS AND/OR THERMOSTATS | $374 | $222 | Not Implemented |
MS0148 # 05 Y:1999 | 05 | 1999 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $5,136 | $1,500 | Implemented |
MS0148 # 06 Y:1999 | 06 | 1999 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,282 | $2,577 | Not Implemented |
MS0148 # 07 Y:1999 | 07 | 1999 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $8,552 | $18,900 | Not Implemented |
MS0148 # 08 Y:1999 | 08 | 1999 | BURN WASTE OIL FOR HEAT | $614 | $2,274 | Not Implemented |