Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

2,380

matching recommendations
Reset
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
LT0142 # 02 Y:1989 02 1989 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $7,542 $442 Implemented
LT0142 # 03 Y:1989 03 1989 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $2,008 $442 Implemented
LT0142 # 04 Y:1989 04 1989 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $2,470 $400 Implemented
LT0142 # 05 Y:1989 05 1989 INSTALL TIMERS AND/OR THERMOSTATS $3,092 $200 Implemented
LT0142 # 06 Y:1989 06 1989 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $3,250 $754 Not Implemented
LT0142 # 07 Y:1989 07 1989 INSTALL / REPAIR INSULATION ON STEAM LINES $423 $100 Implemented
LT0142 # 08 Y:1989 08 1989 REPAIR AND ELIMINATE STEAM LEAKS $3,193 $224 Implemented
MA0136 # 01 Y:1989 01 1989 INSTALL SET-BACK TIMERS $422 $892 Implemented
MA0136 # 02 Y:1989 02 1989 LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA $1,244 $480 Not Implemented
MA0136 # 03 Y:1989 03 1989 SIZE ELECTRIC MOTORS FOR PEAK OPERATING EFFICIENCY $1,017 $1,400 Implemented
MA0136 # 04 Y:1989 04 1989 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $372 $200 Not Implemented
MA0136 # 05 Y:1989 05 1989 RESCHEDULE AND REARRANGE MULTIPLE-SOURCE HEATING SYSTEMS $2,595 $3,602 Not Implemented
TN0358 # 01 Y:1989 01 1989 INSTALL TIMERS AND/OR THERMOSTATS $7,348 $1,020 Implemented
TN0358 # 02 Y:1989 02 1989 USE COMPRESSOR AIR FILTERS $5,608 $100 Implemented
TN0358 # 03 Y:1989 03 1989 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $4,880 $1,000 Implemented
TN0358 # 04 Y:1989 04 1989 RECOVER WASTE HEAT FROM EQUIPMENT $1,687 $2,170 Not Implemented
TN0358 # 05 Y:1989 05 1989 ESTABLISH EQUIPMENT MAINTENANCE SCHEDULE $1,001 $0 Implemented
TN0358 # 06 Y:1989 06 1989 INSTALL SET-BACK TIMERS $1,550 $0 Implemented
TN0358 # 07 Y:1989 07 1989 UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT $1,240 $6,161 Not Implemented
TN0358 # 08 Y:1989 08 1989 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $485 $120 Implemented
TN0358 # 09 Y:1989 09 1989 KEEP LAMPS AND REFLECTORS CLEAN $418 $1,230 Implemented
TN0358 # 10 Y:1989 10 1989 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $310 $621 Implemented
TN0361 # 01 Y:1989 01 1989 ADJUST VENTS TO MINIMIZE ENERGY USE $30,604 $6,500 Not Implemented
TN0361 # 02 Y:1989 02 1989 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $13,381 $1,110 Implemented
TN0361 # 03 Y:1989 03 1989 USE RADIANT HEATER FOR SPOT HEATING $2,488 $5,550 Implemented