IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

2,500

matching recommendations
Reset
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
OD0011 # 02 Y:1994 02 1994 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $661 $683 Not Implemented
OD0011 # 03 Y:1994 03 1994 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT $16,089 $3,300 Implemented
OD0011 # 04 Y:1994 04 1994 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $5,394 $9,618 Implemented
OD0011 # 05 Y:1994 05 1994 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $1,970 $927 Implemented
OD0011 # 06 Y:1994 06 1994 TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME $1,613 $860 Implemented
OD0011 # 07 Y:1994 07 1994 RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS $1,051 $0 Implemented
WV0044 # 01 Y:1994 01 1994 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $68 $687 Implemented
WV0044 # 02 Y:1994 02 1994 USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING $6,479 $4,000 Not Implemented
WV0044 # 03 Y:1994 03 1994 RECOVER WASTE HEAT FROM EQUIPMENT $13,270 $548 Not Implemented
WV0044 # 04 Y:1994 04 1994 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $4,195 $1,032 Implemented
WV0044 # 05 Y:1994 05 1994 USE SYNTHETIC LUBRICANT $3,038 $0 Implemented
WV0043 # 01 Y:1994 01 1994 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $123 $687 Implemented
WV0043 # 02 Y:1994 02 1994 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $7,021 $6,120 Not Implemented
WV0043 # 03 Y:1994 03 1994 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $787 $500 Implemented
WV0043 # 04 Y:1994 04 1994 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $399 $372 Not Implemented
WV0043 # 05 Y:1994 05 1994 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $3,644 $100 Implemented
WV0043 # 06 Y:1994 06 1994 RECOVER WASTE HEAT FROM EQUIPMENT $1,788 $530 Not Implemented
WV0043 # 07 Y:1994 07 1994 INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT $9,680 $6,985 Not Implemented
OD0009 # 01 Y:1994 01 1994 USE A LESS EXPENSIVE METHOD OF WASTE REMOVAL $9,540 $7,075 Not Implemented
OD0009 # 02 Y:1994 02 1994 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $1,145 $800 Implemented
OD0009 # 03 Y:1994 03 1994 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $1,516 $2,392 Not Implemented
OD0009 # 04 Y:1994 04 1994 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $4,987 $5,625 Not Implemented
OD0009 # 05 Y:1994 05 1994 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $648 $498 Implemented
OD0009 # 06 Y:1994 06 1994 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $3,854 $13,330 Implemented
OD0009 # 07 Y:1994 07 1994 PAY UTILITY BILLS ON TIME $481 $0 Implemented