Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
3,777
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
RU0149 # 02 Y:1992 | 02 | 1992 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $1,376 | $3,850 | Not Implemented |
RU0149 # 03 Y:1992 | 03 | 1992 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $646 | $0 | Not Implemented |
RU0149 # 04 Y:1992 | 04 | 1992 | UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT | $900 | $5,500 | Not Implemented |
RU0149 # 05 Y:1992 | 05 | 1992 | INSTALL TIMERS AND/OR THERMOSTATS | $5,738 | $478 | Not Implemented |
RU0149 # 06 Y:1992 | 06 | 1992 | APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES | $2,251 | $0 | Not Implemented |
RU0150 # 01 Y:1992 | 01 | 1992 | IMPROVE LUBRICATION PRACTICES | $4,940 | $2,000 | Not Implemented |
RU0150 # 02 Y:1992 | 02 | 1992 | INSTALL EFFICIENT RECTIFIERS | $100,936 | $125,000 | Not Implemented |
RU0150 # 03 Y:1992 | 03 | 1992 | RECOVER AND REUSE COOLING WATER | $14,788 | $2,700 | Not Implemented |
RU0150 # 04 Y:1992 | 04 | 1992 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $25,123 | $44,000 | Not Implemented |
RU0150 # 05 Y:1992 | 05 | 1992 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $517 | $30 | Not Implemented |
RU0150 # 06 Y:1992 | 06 | 1992 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $2,376 | $500 | Not Implemented |
RU0150 # 07 Y:1992 | 07 | 1992 | OPTIMIZE PLANT POWER FACTOR | $5,770 | $0 | Not Implemented |
RU0150 # 08 Y:1992 | 08 | 1992 | USE WASTE HEAT TO PRODUCE STEAM TO DRIVE A STEAM TURBINE-GENERATOR | $123,105 | $327,000 | Not Implemented |
SD0018 # 01 Y:1992 | 01 | 1992 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $92 | $233 | Implemented |
SD0018 # 02 Y:1992 | 02 | 1992 | USE MOST EFFICIENT EQUIPMENT AT IT'S MAXIMUM CAPACITY AND LESS EFFICIENT EQUIPMENT ONLY WHEN NECESSARY | $870 | $620 | Implemented |
SD0018 # 03 Y:1992 | 03 | 1992 | RE-SIZE CHARGING OPENINGS OR ADD MOVABLE COVER OR DOOR | $1,562 | $120 | Implemented |
SD0018 # 04 Y:1992 | 04 | 1992 | RECOVER WASTE HEAT FROM EQUIPMENT | $1,764 | $551 | Implemented |
SD0018 # 05 Y:1992 | 05 | 1992 | RECOVER WASTE HEAT FROM EQUIPMENT | $635 | $729 | Not Implemented |
SD0018 # 06 Y:1992 | 06 | 1992 | SCHEDULE BAKING TIMES OF SMALL AND LARGE COMPONENTS | $417 | $0 | Implemented |
SD0018 # 07 Y:1992 | 07 | 1992 | INSTALL SET-BACK TIMERS | $3,338 | $7,500 | Implemented |
SD0018 # 08 Y:1992 | 08 | 1992 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $1,830 | $600 | Implemented |
SD0018 # 09 Y:1992 | 09 | 1992 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,375 | $3,300 | Not Implemented |
SD0018 # 10 Y:1992 | 10 | 1992 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $593 | $0 | Implemented |
SD0018 # 11 Y:1992 | 11 | 1992 | KEEP LAMPS AND REFLECTORS CLEAN | $4,343 | $10,788 | Implemented |
SD0018 # 12 Y:1992 | 12 | 1992 | USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE | $14,051 | $2,500 | Implemented |