IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

212

matching recommendations
Reset
NAICS 3222 Converted Paper Product Manufacturing
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
SF0357 # 02 Y:2008 02 2008 RE-USE OR RECYCLE HOT OR COLD PROCESS EXHAUST AIR $27,148 $12,102 Not Implemented
SF0357 # 03 Y:2008 03 2008 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $428 $728 Not Implemented
SF0357 # 04 Y:2008 04 2008 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $6,858 $16,291 Not Implemented
SF0357 # 05 Y:2008 05 2008 INSTALL ADEQUATE DRYERS ON AIR LINES TO ELIMINATE BLOWDOWN $5,290 $16,144 Not Implemented
SF0357 # 06 Y:2008 06 2008 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $71,962 $222,664 Not Implemented
SF0357 # 07 Y:2008 07 2008 REPLACE HYDRAULIC / PNEUMATIC EQUIPMENT WITH ELECTRIC EQUIPMENT $1,645 $6,343 Not Implemented
SF0357 # 08 Y:2008 08 2008 SHUT OFF STEAM TRAPS ON SUPER HEATED STEAM LINES WHEN NOT IN USE $1,741 $0 Not Implemented
SF0357 # 09 Y:2008 09 2008 REPAIR AND ELIMINATE STEAM LEAKS $1,347 $140 Not Implemented
SF0357 # 10 Y:2008 10 2008 REPAIR OR REPLACE STEAM TRAPS $3,011 $294 Not Implemented
SF0357 # 11 Y:2008 11 2008 INSTALL / REPAIR INSULATION ON STEAM LINES $4,263 $2,834 Not Implemented
SF0357 # 12 Y:2008 12 2008 UPGRADE CONTROLS ON COMPRESSORS $8,305 $25,703 Not Implemented
SF0357 # 13 Y:2008 13 2008 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $2,817 $15,233 Not Implemented
SF0326 # 01 Y:2006 01 2006 REMOVE OR CLOSE OFF UNNEEDED COMPRESSED AIR LINES $29,674 $0 Implemented
SF0326 # 02 Y:2006 02 2006 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $8,158 $0 Not Implemented
SF0326 # 03 Y:2006 03 2006 REMOVE OR CLOSE OFF UNNEEDED COMPRESSED AIR LINES $18,476 $5,600 Not Implemented
SF0326 # 04 Y:2006 04 2006 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $19,076 $12,276 Implemented
SF0326 # 05 Y:2006 05 2006 UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT $28,919 $17,664 Not Implemented
SF0326 # 06 Y:2006 06 2006 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $51,157 $38,849 Implemented
SF0326 # 07 Y:2006 07 2006 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $9,265 $7,288 Not Implemented
SF0326 # 08 Y:2006 08 2006 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $3,776 $3,414 Not Implemented
SF0326 # 09 Y:2006 09 2006 REMOVE OR CLOSE OFF UNNEEDED COMPRESSED AIR LINES $11,637 $11,689 Not Implemented
SF0326 # 10 Y:2006 10 2006 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $4,184 $5,312 Not Implemented
SF0326 # 11 Y:2006 11 2006 OPTIMIZE PLANT POWER FACTOR $5,083 $8,900 Not Implemented
SF0326 # 12 Y:2006 12 2006 INSTALL ADEQUATE DRYERS ON AIR LINES TO ELIMINATE BLOWDOWN $9,275 $45,540 Not Implemented
SF0320 # 01 Y:2006 01 2006 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $528 $488 Implemented