Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
61
matching recommendationsSIC | 2013 | Sausages And Other Prepared Meats |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
CO0067 # 12 Y:1986 | 12 | 1986 | INSTALL TIMERS AND/OR THERMOSTATS | $661 | $79 | Implemented |
CO0067 # 09 Y:1986 | 09 | 1986 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,130 | $250 | Implemented |
CO0067 # 08 Y:1986 | 08 | 1986 | INCREASE AMOUNT OF CONDENSATE RETURNED | $150 | $80 | Implemented |
CO0067 # 05 Y:1986 | 05 | 1986 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $5,899 | $300 | Implemented |
CO0067 # 04 Y:1986 | 04 | 1986 | INSTALL / REPAIR INSULATION ON STEAM LINES | $1,266 | $828 | Implemented |
CO0067 # 03 Y:1986 | 03 | 1986 | REDUCE INFILTRATION TO REFRIGERATED AREAS; ISOLATE HOT EQUIPMENT FROM REFRIGERATED AREAS | $3,563 | $2,200 | Implemented |
CO0060 # 10 Y:1986 | 10 | 1986 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $14,473 | $17,000 | Implemented |
CO0060 # 09 Y:1986 | 09 | 1986 | RECOVER WASTE HEAT FROM EQUIPMENT | $1,697 | $1,000 | Implemented |
CO0060 # 07 Y:1986 | 07 | 1986 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $734 | $930 | Implemented |
CO0060 # 05 Y:1986 | 05 | 1986 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $433 | $25 | Implemented |
CO0060 # 03 Y:1986 | 03 | 1986 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $1,357 | $300 | Implemented |
CO0055 # 01 Y:1986 | 01 | 1986 | IMPROVE LUBRICATION PRACTICES | $2,355 | $0 | Implemented |
CO0055 # 10 Y:1986 | 10 | 1986 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,539 | $1,293 | Implemented |
CO0055 # 08 Y:1986 | 08 | 1986 | USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE | $242 | $400 | Implemented |
CO0055 # 07 Y:1986 | 07 | 1986 | CLOSE HOLES AND OPENINGS IN BUILDING SUCH AS BROKEN WINDOWS | $1,802 | $200 | Implemented |
CO0055 # 06 Y:1986 | 06 | 1986 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $533 | $300 | Implemented |
CO0055 # 05 Y:1986 | 05 | 1986 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $417 | $150 | Implemented |
CO0055 # 03 Y:1986 | 03 | 1986 | RECOVER WASTE HEAT FROM EQUIPMENT | $2,244 | $600 | Implemented |
CO0055 # 02 Y:1986 | 02 | 1986 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $1,336 | $300 | Implemented |
CO0041 # 12 Y:1985 | 12 | 1985 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $1,701 | $0 | Implemented |
CO0041 # 07 Y:1985 | 07 | 1985 | AIR CONDITION ONLY SPACE NECESSARY | $2,136 | $225 | Implemented |
CO0041 # 06 Y:1985 | 06 | 1985 | INSTALL / REPAIR INSULATION ON STEAM LINES | $838 | $95 | Implemented |
CO0041 # 05 Y:1985 | 05 | 1985 | AIR CONDITION ONLY SPACE NECESSARY | $1,164 | $2,000 | Implemented |
CO0041 # 04 Y:1985 | 04 | 1985 | INCREASE AMOUNT OF CONDENSATE RETURNED | $139 | $180 | Implemented |
CO0041 # 03 Y:1985 | 03 | 1985 | TURN OFF EQUIPMENT WHEN NOT IN USE | $125 | $200 | Implemented |