IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

130

matching recommendations
Reset
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
KU0418 # 05 Y:1993 05 1993 USE MINIMUM SAFE OVEN VENTILATION $538 $0 Not Implemented
KU0418 # 06 Y:1993 06 1993 INSULATE BARE EQUIPMENT $134 $293 Not Implemented
KU0415 # 06 Y:1993 06 1993 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $230 $100 Implemented
KU0415 # 05 Y:1993 05 1993 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $522 $224 Not Implemented
KU0415 # 04 Y:1993 04 1993 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $159 $225 Not Implemented
KU0415 # 03 Y:1993 03 1993 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $648 $3,996 Not Implemented
KU0415 # 02 Y:1993 02 1993 INSTALL / REPAIR INSULATION ON STEAM LINES $983 $2,255 Implemented
KU0415 # 01 Y:1993 01 1993 REPAIR AND ELIMINATE STEAM LEAKS $1,558 $150 Implemented
KU0414 # 06 Y:1993 06 1993 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $329 $30 Implemented
KU0414 # 07 Y:1993 07 1993 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $148 $150 Not Implemented
KU0414 # 05 Y:1993 05 1993 INSTALL OCCUPANCY SENSORS $453 $600 Implemented
KU0414 # 04 Y:1993 04 1993 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,173 $832 Implemented
KU0414 # 03 Y:1993 03 1993 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $1,703 $520 Not Implemented
KU0414 # 02 Y:1993 02 1993 REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS $1,044 $1,000 Implemented
KU0414 # 01 Y:1993 01 1993 IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS $2,468 $10,400 Not Implemented
KU0413 # 05 Y:1993 05 1993 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $293 $200 Implemented
KU0413 # 04 Y:1993 04 1993 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $682 $113 Implemented
KU0413 # 03 Y:1993 03 1993 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $1,240 $429 Implemented
KU0413 # 02 Y:1993 02 1993 ADD AREA LIGHTING SWITCHES $1,193 $3,969 Not Implemented
KU0413 # 01 Y:1993 01 1993 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $975 $11,826 Not Implemented
OK0418 # 02 Y:1993 02 1993 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,870 $8,403 n/a
OK0418 # 04 Y:1993 04 1993 INSULATE BARE EQUIPMENT $201 $361 n/a
OK0418 # 05 Y:1993 05 1993 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $33 $346 n/a
OK0418 # 03 Y:1993 03 1993 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,411 $3,977 n/a
OK0418 # 01 Y:1993 01 1993 INSTALL TIMERS ON LIGHT SWITCHES IN LITTLE USED AREAS $4,051 $1,350 n/a