Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
428
matching recommendationsSIC | 34 | Fabricated Metal Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
AT0057 # 01 Y:1986 | 01 | 1986 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $355 | $250 | Not Implemented |
AT0057 # 02 Y:1986 | 02 | 1986 | IMPROVE LUBRICATION PRACTICES | $299 | $0 | Implemented |
AT0057 # 03 Y:1986 | 03 | 1986 | USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE | $972 | $1,500 | Implemented |
AT0057 # 04 Y:1986 | 04 | 1986 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $187 | $0 | Implemented |
AT0057 # 05 Y:1986 | 05 | 1986 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $453 | $0 | Implemented |
AT0057 # 06 Y:1986 | 06 | 1986 | COVER OPEN TANKS | $5,222 | $300 | Not Implemented |
AT0057 # 07 Y:1986 | 07 | 1986 | INSULATE BARE EQUIPMENT | $1,261 | $250 | Not Implemented |
TN0288 # 01 Y:1986 | 01 | 1986 | UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT | $4,032 | $8,712 | Not Implemented |
TN0288 # 02 Y:1986 | 02 | 1986 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,648 | $0 | Not Implemented |
TN0288 # 03 Y:1986 | 03 | 1986 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $881 | $120 | Implemented |
TN0288 # 04 Y:1986 | 04 | 1986 | INSTALL SET-BACK TIMERS | $534 | $0 | Implemented |
TN0288 # 05 Y:1986 | 05 | 1986 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $537 | $236 | Implemented |
TN0288 # 06 Y:1986 | 06 | 1986 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $223 | $600 | Implemented |
AT0054 # 01 Y:1986 | 01 | 1986 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $820 | $986 | Implemented |
AT0054 # 02 Y:1986 | 02 | 1986 | IMPROVE LUBRICATION PRACTICES | $4,453 | $0 | Implemented |
AT0054 # 03 Y:1986 | 03 | 1986 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,134 | $0 | Implemented |
AT0054 # 04 Y:1986 | 04 | 1986 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,066 | $150 | Implemented |
AT0054 # 05 Y:1986 | 05 | 1986 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $1,521 | $0 | Implemented |
AT0054 # 06 Y:1986 | 06 | 1986 | COVER OPEN TANKS | $7,949 | $1,850 | Implemented |
AT0054 # 07 Y:1986 | 07 | 1986 | REPAIR FAULTY INSULATION IN FURNACES, BOILERS, ETC | $644 | $500 | Implemented |
AT0054 # 08 Y:1986 | 08 | 1986 | INSTALL / REPAIR INSULATION ON STEAM LINES | $122 | $150 | Implemented |
AT0054 # 09 Y:1986 | 09 | 1986 | RECOVER WASTE HEAT FROM EQUIPMENT | $2,814 | $1,500 | Implemented |
AT0005 # 01 Y:1985 | 01 | 1985 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $490 | $1,183 | Implemented |
AT0005 # 02 Y:1985 | 02 | 1985 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $5,390 | $300 | Implemented |
AT0005 # 03 Y:1985 | 03 | 1985 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $291 | $400 | Implemented |