Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

173

matching recommendations
Reset
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
AT0063 # 01 Y:1987 01 1987 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT $16,207 $5,000 Implemented
AT0063 # 02 Y:1987 02 1987 USE DEMAND CONTROLLER OR LOAD SHEDDER $2,078 $500 Not Implemented
AT0063 # 03 Y:1987 03 1987 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $2,247 $3,793 Implemented
AT0063 # 04 Y:1987 04 1987 TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME $716 $300 Implemented
AT0063 # 05 Y:1987 05 1987 USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE $763 $500 Implemented
AT0063 # 06 Y:1987 06 1987 INSTALL AUTOMATIC STACK DAMPER $346 $800 Not Implemented
AT0063 # 07 Y:1987 07 1987 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $103 $195 Implemented
AT0063 # 08 Y:1987 08 1987 UPGRADE OBSOLETE EQUIPMENT $200 $0 Implemented
AT0063 # 09 Y:1987 09 1987 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $117 $0 Not Implemented
AT0063 # 10 Y:1987 10 1987 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $117 $200 Implemented
AT0063 # 11 Y:1987 11 1987 REDUCE HOT WATER TEMPERATURE TO THE MINIMUM REQUIRED $100 $0 Implemented
AT0064 # 01 Y:1987 01 1987 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $107 $108 Implemented
AT0064 # 02 Y:1987 02 1987 USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE $303 $500 Implemented
AT0064 # 03 Y:1987 03 1987 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT $2,391 $3,000 Not Implemented
AT0064 # 04 Y:1987 04 1987 USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING $2,374 $4,200 Not Implemented
AT0065 # 01 Y:1987 01 1987 USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING $10,589 $3,000 Not Implemented
AT0065 # 02 Y:1987 02 1987 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $12,448 $10,000 Implemented
AT0065 # 03 Y:1987 03 1987 REDESIGN PROCESS $2,779 $6,000 Not Implemented
AT0065 # 04 Y:1987 04 1987 USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE $26,038 $4,000 Not Implemented
AT0065 # 05 Y:1987 05 1987 IMPROVE LUBRICATION PRACTICES $4,191 $0 Not Implemented
AT0065 # 06 Y:1987 06 1987 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $2,960 $1,685 Not Implemented
AT0065 # 07 Y:1987 07 1987 AVOID INTRODUCING HOT, HUMID, OR DIRTY AIR INTO HVAC SYSTEM $1,196 $1,800 Not Implemented
AT0065 # 08 Y:1987 08 1987 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $306 $500 Implemented