Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
113
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UD0329 # 01 Y:1990 | 01 | 1990 | OPTIMIZE PLANT POWER FACTOR | $17,856 | $20,000 | Implemented |
UD0329 # 02 Y:1990 | 02 | 1990 | RECOVER WASTE HEAT FROM EQUIPMENT | $5,309 | $1,000 | Implemented |
UD0329 # 03 Y:1990 | 03 | 1990 | BURN WASTE OIL FOR HEAT | $6,067 | $0 | Implemented |
UD0329 # 05 Y:1990 | 05 | 1990 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $1,223 | $6,240 | Implemented |
UD0329 # 04 Y:1990 | 04 | 1990 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,783 | $7,500 | Implemented |
UD0321 # 02 Y:1990 | 02 | 1990 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $7,310 | $7,500 | Implemented |
UD0321 # 01 Y:1990 | 01 | 1990 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $14,217 | $37,000 | Implemented |
UD0321 # 04 Y:1990 | 04 | 1990 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $10,068 | $14,000 | Not Implemented |
UD0321 # 03 Y:1990 | 03 | 1990 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $2,760 | $1,100 | Implemented |
UD0320 # 01 Y:1990 | 01 | 1990 | USE MOST EFFICIENT EQUIPMENT AT IT'S MAXIMUM CAPACITY AND LESS EFFICIENT EQUIPMENT ONLY WHEN NECESSARY | $1,650 | $0 | Not Implemented |
UD0319 # 03 Y:1990 | 03 | 1990 | MINIMIZE OPERATION OF EQUIPMENT MAINTAINED IN STANDBY CONDITION | $13,053 | $0 | Implemented |
UD0318 # 05 Y:1990 | 05 | 1990 | INSTALL TIMERS AND/OR THERMOSTATS | $10,040 | $5,000 | Not Implemented |
UD0319 # 02 Y:1990 | 02 | 1990 | USE DEMAND CONTROLLER OR LOAD SHEDDER | $1,320 | $0 | Implemented |
UD0319 # 01 Y:1990 | 01 | 1990 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $10,147 | $0 | Implemented |
UD0320 # 02 Y:1990 | 02 | 1990 | INSTALL SET-BACK TIMERS | $1,090 | $0 | Not Implemented |
UD0318 # 04 Y:1990 | 04 | 1990 | USE OPTIMUM SIZE AND CAPACITY EQUIPMENT | $1,599 | $0 | Implemented |
UD0318 # 06 Y:1990 | 06 | 1990 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,103 | $1,680 | Implemented |
UD0318 # 02 Y:1990 | 02 | 1990 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $2,804 | $500 | Implemented |
UD0318 # 07 Y:1990 | 07 | 1990 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,116 | $5,820 | Not Implemented |
UD0318 # 03 Y:1990 | 03 | 1990 | RECOVER WASTE HEAT FROM EQUIPMENT | $1,306 | $300 | Implemented |
UD0320 # 04 Y:1990 | 04 | 1990 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $1,361 | $3,000 | Not Implemented |
UD0319 # 04 Y:1990 | 04 | 1990 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $20,790 | $0 | Implemented |
UD0318 # 01 Y:1990 | 01 | 1990 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $8,002 | $0 | Implemented |
UD0320 # 03 Y:1990 | 03 | 1990 | INSTALL TIMERS AND/OR THERMOSTATS | $1,389 | $4,000 | Not Implemented |
UD0316 # 04 Y:1990 | 04 | 1990 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $6,611 | $0 | Not Implemented |