Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
298
matching recommendationsSIC | 36 | Electronic & Other Electric Equipment |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
OK0171 # 02 Y:1985 | 02 | 1985 | INSTALL TIMERS AND/OR THERMOSTATS | $20,880 | $1,500 | Implemented |
OK0171 # 03 Y:1985 | 03 | 1985 | OPTIMIZE PLANT POWER FACTOR | $690 | $1,315 | Implemented |
OK0171 # 04 Y:1985 | 04 | 1985 | USE ONLY AMOUNT OF AIR NECESSARY TO PREVENT EXPLOSION HAZARD | $4,668 | $50 | Implemented |
OK0171 # 05 Y:1985 | 05 | 1985 | INSULATE BARE EQUIPMENT | $55 | $130 | Implemented |
OK0171 # 06 Y:1985 | 06 | 1985 | MINIMIZE WATER USAGE | $2,464 | $0 | Implemented |
OK0171 # 07 Y:1985 | 07 | 1985 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $557 | $420 | Implemented |
OK0164 # 01 Y:1985 | 01 | 1985 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,930 | $891 | Implemented |
OK0164 # 02 Y:1985 | 02 | 1985 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $304 | $47 | Not Implemented |
OK0164 # 03 Y:1985 | 03 | 1985 | USE RADIANT HEATER FOR SPOT HEATING | $1,900 | $2,215 | Implemented |
OK0164 # 04 Y:1985 | 04 | 1985 | TURN OFF EQUIPMENT WHEN NOT IN USE | $133 | $150 | Implemented |
OK0164 # 05 Y:1985 | 05 | 1985 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $314 | $600 | Implemented |
OK0147 # 01 Y:1984 | 01 | 1984 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $4,160 | $900 | Implemented |
OK0147 # 02 Y:1984 | 02 | 1984 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $509 | $131 | Implemented |
OK0147 # 03 Y:1984 | 03 | 1984 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $2,650 | $6,252 | Implemented |
OK0147 # 04 Y:1984 | 04 | 1984 | HEAT WATER WITH EXHAUST HEAT | $7,174 | $6,955 | Not Implemented |
OK0147 # 05 Y:1984 | 05 | 1984 | USE DEMAND CONTROLLER OR LOAD SHEDDER | $6,120 | $1,236 | Implemented |
OK0147 # 06 Y:1984 | 06 | 1984 | INSTALL / REPAIR INSULATION ON CONDENSATE LINES | $566 | $333 | Implemented |
OK0147 # 07 Y:1984 | 07 | 1984 | REPAIR FAULTY INSULATION IN FURNACES, BOILERS, ETC | $2,671 | $1,647 | Implemented |
OK0147 # 08 Y:1984 | 08 | 1984 | REPAIR FAULTY INSULATION IN FURNACES, BOILERS, ETC | $2,036 | $720 | Implemented |
OK0147 # 09 Y:1984 | 09 | 1984 | INSTALL TIMERS AND/OR THERMOSTATS | $492 | $291 | Implemented |
OK0147 # 10 Y:1984 | 10 | 1984 | TURN OFF EQUIPMENT WHEN NOT IN USE | $6,362 | $1,090 | Implemented |
OK0142 # 01 Y:1984 | 01 | 1984 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $164 | $268 | Implemented |
OK0142 # 02 Y:1984 | 02 | 1984 | REDUCE VENTILATION AIR | $125 | $0 | Implemented |
OK0142 # 03 Y:1984 | 03 | 1984 | USE DIRECT AIR SUPPLY TO EXHAUST HOODS | $100 | $81 | Not Implemented |
OK0142 # 04 Y:1984 | 04 | 1984 | INSULATE BARE EQUIPMENT | $488 | $58 | Implemented |